Hot-film anemometer velocity measurements of arterial blood flow in horses



Hot-film anemometer velocity measurements of arterial blood flow in horses



Circulation Research 34(2): 193-203



Blood velocity measurements were carried out using a constant-temperature hot-film anemometer system in both anaesthetized and conscious horses. Catheter probes were used to measure velocity wave forms in conscious horses and L-shaped needle probes inserted by direct vessel puncture were used to measure the profiles in the thoracic and abdominal aorta regions of anaesthetized, open-chest horses. Both catheter and L-shaped probes were used for coronary velocity wave-form measurements. The flow conditions were characterized by peak Reynolds numbers of 200-10000 and unsteadiness parameter of 2-30. These measurements indicate that in the thoracic aorta the flow at peak systole is largely inviscid, with a thin-wall boundary layer; in the abdominal aorta the flow is more fully developed but skewed due to branching effects. Highly disturbed flows were observed in the thoracic aorta of both anaesthetized and conscious horses, but not in the abdominal aortic region or in the coronary arteries. Hence the flow in the arterial system, although in many cases laminar and disturbance-free, is extremely varied in character. It may be asymmetric and certainly is not representative of fully developed, Poiseuille flow.

(PDF emailed within 0-6 h: $19.90)

Accession: 000109681

Download citation: RISBibTeXText

PMID: 4272693

DOI: 10.1161/01.RES.34.2.193



Related references

Hot film anemometer velocity measurements of arterial flow in horses. Federation Proceedingspart 1: 379, 1974

The application of hot-film anemometer to blood flow velocity measurements. Iyo Denshi to Seitai Kogaku. Japanese Journal of Medical Electronics and Biological Engineering 16(2): 130-133, 1978

Flow studies with a blood simulant system abstract inst hot film anemometer probe blood flow velocity model. Virginia Journal of Science 19(3): 191, 1968

Analysis of the dynamic properties of a hot film anemometer system for blood velocity measurements in humans. Medical & Biological Engineering & Computing 25(2): 195-200, 1987

Measurement of instantaneous blood flow velocity in major vessels using a thin film anemometer. Journal of Physiology 204(2): 72p-73p, 1969

Hot-film anemometer measurements of velocity decay in Karman trail vortexes. Journal of Geophysical Research 75(6): 1033-1039, 1970

Use of hot film system for arterial blood velocity measurements. Journal of Physiology 207(2): 84p-85p, 1970

Evaluation of the hot-film technique for arterial blood velocity measurements. Journal of Physiology 204(1): 47p-48p, 1969

The hot film anemometer a method for blood velocity determination 1. in vitro comparison with the electro magnetic blood flowmeter. European Surgical Research 12(2): 140-148, 1980

The hot film anemometer a method for blood velocity determination 2. in vivo comparison with the electro magnetic blood flowmeter. European Surgical Research 12(2): 149-158, 1980

Patient safety unit for a hot-film anemometer, used for blood-velocity determination in humans. Medical & Biological Engineering & Computing 20(5): 625-627, 1982

An analysis of the dynamic properties of a hot film anemometer system for blood velocity determination. Life Support Systemspl. 1: 82, 1984