Removal of material from stagnant zones in dairy piping



Removal of material from stagnant zones in dairy piping



Lebensmittel Wissenschaft und Technologie 11(6): 330-332



The kinetics of removal of microorganisms from stagnant zones in a milk pasteurization line are evaluated. A 1-in diam. stainless steel "T" piece fitted in a 5-m long 1-in diam. straight pipe was used to simulate a typical stagnant zone, and the removal of water and milk from it was measured using 51 Cr as radioactive tracer. The process was studied with the aid of a diffusion-type model which yielded removal coeff. for the tracer ions and for labelled bacteria.

Please choose payment method:






(PDF emailed within 1 workday: $29.90)

Accession: 000734942

Download citation: RISBibTeXText


Related references

Enhancements to the geochemical model PHREEQC; 1D advection and dispersion, diffusion to stagnant zones, and reaction kinetics zones, and reaction kinetics. Eos, Transactions, American Geophysical Union 78(17, Suppl, 1997

Piping potential of weak zones under concrete dams. Journal of the Geotechnical Engineering Division 108(GT3): 488-493, 1982

Treatment of stagnant zones in riverine advection-dispersion. Journal of Hydraulic Engineering 129(6): 470-473, 2003

Interpretation of environmental tracers in groundwater systems with stagnant water zones. Isotopes in Environmental and Health Studies 40(1): 21-33, 2004

Angiographic evidence of stagnant flow zones in the carotid circulation of anesthetized dogs. Investigative Radiology 8(1): 28-32, 1973

Removal of interior scale from digester gas piping. J Water Pollut Contr Fed 37(10): 1389-1391, 1965

Efficacy of Biofilm Removal From Hemodialysis Piping. Nephro-UrologyMonthly8(5):E39332, 2016

Numerical simulation and measurement of liquid hold-up in biporous media containing discrete stagnant zones. Philosophical Transactions - Royal Society Mathematical, Physical and Engineering Sciences, 2002

Numerical simulation and measurement of liquid hold-up in biporous media containing discrete stagnant zones. Philosophical Transactions. Series A Mathematical Physical and Engineering Sciences 360(1792): 521-534, 2002

Hydrogeological map of Russian Federation, scale 12,500,000; zones of hampered water exchange and stagnant regime. Razvedka i Okhrana Nedr, 2009

Influence of stagnant zones on transient and asymptotic dispersion in macroscopically homogeneous porous media. Physical Review Letters 88(23): 234501, 2002

The dairy sector has not remained stagnant. Informatore Agrario 57(31): 10-11, 2001

The cleaning of glass piping in dairy plants. J. Milk Food Tech, 16: 1, 9-14, 1953

Steam piping system for dairy plant. Indian Dairyman 42(10): 413-417, 1990

Glass sanitary piping in dairy plants. Milk Dealer 39(1): 42-43, 134-138, 1949