Hot-wire anemometer behaviour in low velocity air flow



Hot-wire anemometer behaviour in low velocity air flow



Journal of Physics E: Scientific Instruments 14(1): 46-51



The behaviour characteristics of a commercially available hot-wire anemometer have been examined for velocities < 0.1 m/s in both horizontal and vertical air flows. The orientation of the probe in a horizontal flow was found to have a definite effect on velocity measurements, and a lower limit to the reliable application of hot-wire anemometry has been evaluated for a particular type of probe.

Please choose payment method:






(PDF emailed within 0-6 h: $19.90)

Accession: 000903319

Download citation: RISBibTeXText

DOI: 10.1088/0022-3735/14/1/013


Related references

Measurement of gas flow velocity: anemometer with a vibrating hot wire. Review of Scientific Instruments 81(1): 015101, 2010

A fully compensated hot/cold wire anemometer system for unsteady flow velocity and temperature measurements. Measurement Science and Technology 1(5): 425-430, 1990

Dynamic response of a hot-wire anemometer. Part I: A marginally elevated hot-wire probe for near-wall velocity measurements. Measurement Science and Technology 9(5): 751-763, 1998

The dynamic response of a hot-wire anemometer: Iii. Voltage-perturbation versus velocity-perturbation testing for near-wall hot-wire/film probes. Measurement Science and Technology 10(3): 152-169, 1999

On the Comparison of Wind-velocity measured with a Pendulum-anemometer, Dines' Pressure Tube Anemometer and Robinson's Cup Anemometer. Journal of the Meteorological Society of Japan 15(8): 338-341, 1937

Intrabronchial measurement of air velocity by hot wire anemometer (broncho-anemography). Nihon Kyobu Shikkan Gakkai Zasshi 10(10): 542-549, 1972

Dynamic behaviour of the constant temperature anemometer due to thermal inertia of the wire. Flow, Turbulence and Combustion 32(5): 509-518, 1976

Hot-wire-anemometer study of the entry flow in a curved duct. Journal of Fluid Mechanics 165(-1): 335, 1986

Observation upon the blood flow through skeletal muscle by the use of the hot wire anemometer. Amer Jour Physiol 95(3): 554-560, 1930

Evaluation of a constant temperature hot wire anemometer for respiratory gas flow measurements. Medical & Biological Engineering & Computing 17(2): 211-215, 1979

Hot film anemometer velocity measurements of arterial flow in horses. Federation Proceedingspart 1: 379, 1974

The application of hot-film anemometer to blood flow velocity measurements. Iyo Denshi to Seitai Kogaku. Japanese Journal of Medical Electronics and Biological Engineering 16(2): 130-133, 1978

A critical evaluation of the explicit data analysis algorithm for a crossed wire anemometer in highly turbulent isotropic flow. Measurement Science and Technology 1(8): 775-781, 1990

Hot-film anemometer velocity measurements of arterial blood flow in horses. Circulation Research 34(2): 193-203, 1974

Flow studies with a blood simulant system abstract inst hot film anemometer probe blood flow velocity model. Virginia Journal of Science 19(3): 191, 1968