Retrofitting swine buildings for wood-heated air tempering



Retrofitting swine buildings for wood-heated air tempering



Paper, American Society of Agricultural Engineers (83-4075): 13 pp



Methods to assist 3 pig producers to heat buildings effectively and inexpensively with wood are discussed. Two cases used a simple wood stove in combination with existing ventilation systems for heat distribution. The third incorporated concrete heat exchangers for hot water zone heating.

(PDF emailed within 1 workday: $29.90)

Accession: 001246829

Download citation: RISBibTeXText


Related references

Strengthening and retrofitting of reinforced concrete buildings. Individual Studies by Participants at the International Institute of Seismology and Earthquake Engineering 34(Pages 189-201, 1998

An expert system to support retrofitting of masonry buildings. EUR (Luxembourg): ; Pages 49-56. 1997., 1997

Respiratory health of workers exposed to swine confinement buildings only or to both swine confinement buildings and dairy barns. Scandinavian Journal of Work, Environment & Health 17(4): 269-275, 1991

Termite physical barriers: current status of retrofitting Granitgard around 'mock-up' buildings. Document International Research Group on Wood Preservation ( IRG/WP/94-10057): 5 pp., 1994

Termite physical barriers: update on retrofitting Granitgard around 'mock-up' buildings after four years. Document International Research Group on Wood Preservation ( IRG/WP/96-10140): 6 pp., 1996

Cost benefit analysis of earthquake protection programme through retrofitting of non-engineered buildings. Proceedings of the World Conference on Earthquake Engineering 12(2000, 2000

Microclimate of heated and not heated farrowing swine houses in the central and eastern Siberia. Problemy zoogig i vet sanit na zhivotnovod fermakh: 05-106, 1970

A local campaign for retrofitting buildings by Sumida quakeproof reinforcement promotion conference, Sumida City, Tokyo. Chigaku Zasshi = Journal of Geography 116(3-4): 536-541, 2007

Comparative examination of various possibilities of tempering wood to withstand destructive fungi. Part 1: resistance to fungi: a comparison of a range of unconventional wood protective methods with commercially available products. Schweizerische Zeitschrift fur Forstwesen 156(6): 177-187, 2005

How farm buildings are heated. Teho ) 36-37, 1980

Air tempering for swine ventilation by earth heat exchanger. Canadian Agricultural Engineering 33(2): 404, 1991

Swine forbidden? Intensified accepted procedures for swine buildings. 1975

Condensation nuclei in the air of artificially heated buildings. Annali Della Sanita Pubblica 13(6): 1569-1581, 1952

Earth-tube as air tempering systems for swine farrow-nursery housing. Transactions of the ASAE American Society of Agricultural Engineers 27(4): 1154-1162, 1984

Production rates of toxic gases from liquid swine manure health implications for workers and animals in swine confinement buildings. Biological Wastes 24(3): 161-174, 1988