EurekaMag.com logo
+ Site Statistics
References:
53,623,987
Abstracts:
29,492,080
+ Search Articles
+ Subscribe to Site Feeds
EurekaMag Most Shared ContentMost Shared
EurekaMag PDF Full Text ContentPDF Full Text
+ PDF Full Text
Request PDF Full TextRequest PDF Full Text
+ Follow Us
Follow on FacebookFollow on Facebook
Follow on TwitterFollow on Twitter
Follow on LinkedInFollow on LinkedIn

+ Translate

External corrosion - how long before pipework inspection?



External corrosion - how long before pipework inspection?



CEP Technical Manual 25: 47-53



An extensive inspection was made at an ammonia plant in order to seek out and rectify, where necessary, external corrosion of pipework at liquid ammonia storage and handling facilities. Details are given. The main types of external corrosion found were: pitting at plinths and other pipe supports; pitting on the underside of pipes, especially along the drip line; corrosion adjacent to small bore nozzles on larger pipes; and corrosion on bends.

(PDF 0-2 workdays service: $29.90)

Accession: 001364820

Download citation: RISBibTeXText



Related references

Detection of biofilms associated with pitting corrosion of copper pipework in Scottish hospitals. Biocorrosion Proceedings of a joint meeting between the Biodeterioration Society and the French Microbial Corrosion Group, Paris, France, 13-14 September 1988: 99-117, 1989

Corrosion and protection against corrosion in long distance heating systems. Husmann, Wilhelm (Edited By) Vom Wasser Ein Jahrbuch Fur Wasserchemie Und Wasserreinigungstechnik, Band Xxxvi (From Water An Annual For Hydrochemistry And Water Purification Techniques, Vol Xxxvi ) 520p Illus Verlag Chemie, Gmbh: Weinheim-Bergstr, W Germany 451-463, 1970

Alteration of metal in CR2 chondrites as analogue for long term corrosion processes; Raman studies of corrosion RIMS. Abstracts of Papers Submitted to the Lunar and Planetary Science Conference 40: 1296, 2009

Corrosion and erosion monitoring in plates and pipes using constant group velocity Lamb wave inspection. Ultrasonics 54(7): 1832-1841, 2014

Technical problems on meat inspection. IV. Detailed inspection. 2. inspection technique and criteria of judgment of verrucous endocarditis and pyemia in meat inspection. Journal of the Japan Veterinary Medical Association: 30 (3) 154-157, 1977

External can corrosion. 1982

Pipework must be tough and resilient. Health Estate 69(9): 106-108, 2016

External corrosion in distribution systems. American Water Works Association Journal 81(10): 45-52, 1989

Economic thickness of pipework insulation. Hospital Engineering 34(8): 25-27, 1980

Glass as a drainage pipework material. Hospital Development 8(2): 44-45, 1980

Inhibition of the external corrosion of tinplate cans. Industria conserve: t 50 (3) 203-208, 1975

Pumps and pipework for greenhouse heating systems. Mechanization leaflet for farmers and growers: 3, 1976

Proceedings, external corrosion of metal food containers. 1998

Near surface external casing corrosion in Alaska; cause and mitigation. Abstracts with Programs - Geological Society of America 38(5): 22, 2006

External corrosion to concrete sewers a case study. Urban Water Journal 9(6): 429-434, 2012