Basic studies on the cooling of dried milk during pneumatic transport






Memoirs of the Faculty of Agriculture, Hokkaido University 14(3): 201-209

Basic studies on the cooling of dried milk during pneumatic transport

An experimental system having a transport tube with a fan, electric heater and water-cooled heat exchanger and with a separator and a return tube entering below the heater, was tested in 19 trials using only air, in 12 trials with powdered soda glass and in 12 trials with dried skim milk. The overall coeff. of heat transfer with air alone increased with increasing air flow-rate and temp. and cooling-water flow-rate.


Accession: 001535110



Related references

Vinogradov, V.N.; Medovar, L.E., 1983: Cooling dried milk products during pneumatic transport. A system is described for cooling dried milk by air, precooled by water coolers, during conveying from the drier to the packaging station. The technical characteristics of the system and design of the air cooler are discussed. Calculations charact...

Schroter, K., 1968: New plant for cooling, weighing, pneumatic transportation and storage of dried milk-substitute fat concentrate. The plant handles a 50%-fat milk substitute for calf feeding. The substitute passes at a rate of 1.2 m3/h from the spray-drier by worm conveyor to the continuously operating fluidized bed cooler where it is cooled from 60 to 30 degrees C and the f...

Rodin, V.D.; Sinyatkin, V.S., 1976: Pneumatic transport of dried skim-milk. A system for pneumatic transport of roller dried skim-milk (patent applied for) is briefly described. The dried product from the driers is passed by a worm conveyor to a high-pressure blower from where it is blown by air with concurrent drying and...

Davidson, P.; Fetisova, N., 1965: Experimental installation for pneumatic transport of dried milk. A study was made of some physical properties of dried milk which affect its transport by pneumatic means. In the samples of whole dried milk tested the particles < 30 mu m. in size represented on an average 61-4% of the total particle numbers b...

Anonymous, 1976: New installation for cooling, weighing, pneumatic transport and storing a powdery milk fat concentrate. An installation (the first of its kind) for cooling, weighing, transporting and storing dried fat concentrates (50% fat) in operation in a German dried milk factory (output about 1.2 m3 product/h) is described. The product is passed by a screw con...

Cesul, J.; Filipkowski, S.; Komar, M., 1966: Studies on the cooling of dried milk by means of fluidization. Orientation experiments carried out in the laboratory plant described in DSA 27 showed that dried skim-milk can be cooled by the fluidization principle from an initial temp, of 60-70 degrees C, simulating that at which it would leave a drying plan...

Heldman, D.; Wang, P.; Chen, A., 1971: Effectiveness of pneumatic conveying systems for cooling spray-dried food products. Journal of food science: 36 (2) 311-314

Anonymous, 1980: Analysis of dried milk and dried milk products. II. Determination of the solubility of dried milk, dried whey and dried buttermilk (reference method). The method involves gravimetric estimation of the moisture content of the sample. A test portion of the sample (4.9-5.1 g for dried whole milk, 3.4-3.6 g for dried skim milk or dried buttermilk, 2.5-2.7 g for dried whey) is wetted and then mechani...

Malczewski, J.S.kora, B., 1977: Pneumatic transport of dried sugarbeet pulp. Gazeta cukrownicza: 95 (1) 6-8

Itoh K., 1985: Cooling rates of powder milk during pneumatic transportation. The overall coefficient of heat transfer of air increased with the increasing of air and cooling water flow and air temperature. The overall coefficient of heat transfer was 26.88 to 27.10 (kcal/m2 h .degree. C) for air temperature 60.degree. C, a...