Control of milk coagulation process using thermal conductivity measurement (hot wire method). II



Control of milk coagulation process using thermal conductivity measurement (hot wire method). II



Industrie Alimentari 25(249): 449-456



The coagulation process of both pasteurized and raw milk was monitored by measuring heat conductivity variation, and the dynamic-mechanical properties by means of a hot wire and dynamic spectrometer resp. A detailed description of the latter technique is also given. A comparison of results based essentially on coagulation time was done and a microstructural interpretation proposed, based on the mechanism of collodial gel formation.

(PDF emailed within 1 workday: $29.90)

Accession: 001554628

Download citation: RISBibTeXText



Related references

Measurement of thermal conductivity of rocks by the heated wire method. Geologija 25(2): 335-339, 1982

The boundary induced error on the measurement of thermal conductivity by transient hot wire method. Measurement Science and Technology 6(5): 467-471, 1995

Measurement of the thermal conductivity of carbon nanotube--tissue phantom composites with the hot wire probe method. Annals of Biomedical Engineering 39(6): 1745-1758, 2011

An apparatus for the routine measurement of thermal conductivity of materials for building application based on a transient hot-wire method. Applied Thermal Engineering 27(14-15): 2495-2504, 2007

Note: Thermal conductivity measurement of individual porous polyimide fibers using a modified wire-shape 3ω method. Review of Scientific Instruments 89(9): 096112-096112, 2018

Effects of rennet treatment and water content on thermal conductivity of skim milk Measured by the hot wire method. Journal of food science 48(5): 1492-1496, 1983

In line objective measurement of the process of milk curd formation by the hot wire method. Journal of the Japanese Society for Food Science & Technology (Nippon Shokuhin Kogyo Gakkaishi) 35(1): 52-56, 1988

Thermal conductivity of nineteen igneous rocks; I, Application of the needle probe method to the measurement of the thermal conductivity of rock. Physics of the Earth and Planetary Interiors 5(none): 0-156, 1972

Measurement of the thermal conductivity of frost by a transient hot-wire technique. Journal of Geophysical Research 75(21): 4180-4183, 1970

Measurement of Thermal Conductivity of Porcine Liver in the Temperature Range of Cryotherapy and Hyperthermia (250~315k) by A Thermal Sensor Made of A Micron-Scale Enameled Copper Wire. Cryo Letters 37(6): 427-431, 2017

Parallel wire method for the determination of thermal conductivity and diffusivity of soils. Soil Technology 4(2): 191-194, 1991

Estimation of the effective thermal conductivity of rocks in situ by cuttings; Part 1, Development of a rapid measurement method for the effective thermal conductivity of cuttings-water mixture beds at high temperatures and pressures. Sekiyu Gijutsu Kyokaishi = Journal of the Japanese Association of Petroleum Technology 54(2): 111-121, 1989

Measurement of fluid viscosity and blood coagulation by a hot wire method. Biorheology 29(1): 93, 1992

Measurement of soil thermal conductivity with thermal needle method. Yen Tu Li Hsueh = Rock and Soil Mechanics 10(1): 61-65, 1989

A dual-thermistor probe for absolute measurement of thermal diffusivity and thermal conductivity by the heat pulse method. Measurement Science and Technology 14(8): 1396-1401, 2003