Indirect measurement of blood pressure: studies in the colic horse



Indirect measurement of blood pressure: studies in the colic horse



Pferdeheilkunde 3(6): 323-326, 329-331



For indirect measurements of blood pressure in the tail arteries of 32 healthy horses of both sexes, aged 3-19 years, a fully automatic oscillometer fitted with a cuff 8.4 cm wide and 17 cm long was used. The average values of 335 measurements were calculated as 120.33 mm Hg for the systolic, 75.81 mm Hg for the intermediate and 49.78 mm Hg for the diastolic pressure.

(PDF 0-2 workdays service: $29.90)

Accession: 001615696

Download citation: RISBibTeXText



Related references

Indirect measurement of mean blood pressure in the horse. Southwestern veterinarian: er 23 (4) 289-294, 1970

The indirect measurement of arterial blood pressure in the horse. Equine Veterinary Journal 7(1): 22-26, 1975

A method for indirect measurement of arterial blood pressure in the horse. Australian Veterinary Journal 53(4): 163-166, 1977

Indirect measurement of mean blood pressure in the normotensive and hypotensive horse. Equine Veterinary Journal: 194, 1979

An ultrasonic method for indirect blood pressure measurement in the horse. Journal of Equine Medicine & Surgery 3(1): 16-23, 1979

Monitoring circulation in the horse during sedation and anesthesia by indirect blood pressure measurement. Berliner und Munchener Tierarztliche Wochenschrift 98(5): 166-173, 1985

Critical comparison of palpatoric, oscillatoric and ultrasonic doppler methods for indirect measurement of blood pressure in dog, horse and cattle. 1979

Indirect measurement of blood pressure as a guide to the efficacy of fluid therapy in equine shock: a case report Horse, acute circulatory failure. Journal of equine veterinary science(1): 24-27, 1983

Comparison of invasive blood pressure measurement in the aorta with indirect oscillometric blood pressure measurement at the wrist and forearm. Zeitschrift für Kardiologie 84(9): 675-685, 1995

Significance of blood pressure self-measurement as compared with office blood pressure measurement and ambulatory 24-hour blood pressure measurement in pharmacological studies. Blood Pressure Monitoring 8(4): 169-172, 2003

Studies on the indirect measurement of blood pressure I Sources of error in the Riva Rocci method. Amer Jour Physiol: 48-67, 1933

Studies on the limit point criteria in the graphic recording of indirect measurement of blood pressure. Zeitschrift für die Gesamte Innere Medizin und Ihre Grenzgebiete 11(11): 511-518, 1956

Problems and errors in the measurement and interpretation of blood pressure. Part 4. New developments in indirect blood pressure determination. Mmw, Munchener Medizinische Wochenschrift 122(38): Suppl 53-8, 1980

Paediatric blood pressure measurement The difficulties in finding the ideal indirect blood pressure monitor. Pediatric Nephrology 11(5): C44, 1997

Does the Penaz indirect continuous blood pressure measurement represent progress in blood pressure monitoring?. Biomedizinische Technik. Biomedical Engineering 35 Suppl 3: 113-114, 1990