Silage pressures in glass-fibre reinforced plastic silos



Silage pressures in glass-fibre reinforced plastic silos



Grundlagen der Landtechnik 37(5): 166-172



Vertical and horizontal pressures of sugarbeet pulp and tops were measured at various levels in 3.5-m-diam., 10-m-high glassfibre-reinforced, thin-walled tower silos by a newly developed method using cushions of thin, soft PVC. The weight of silage between 2 levels of measurement, settling of the fodder and its release of liquor were measured, enabling calculation of the friction pressures on the walls.

(PDF 0-2 workdays service: $29.90)

Accession: 001684093

Download citation: RISBibTeXText



Related references

Plastic tower silos reinforced with glass fibre: also safe after several years!. FAT Berichte, Switzerland ( 536): 12 pp., 1999

Filters from glass-fibre-reinforced plastic. Gidrotekhnika i melioratsiia: 9 90-94, 1975

Improvement in creep behaviour of wood based materials by glass fibre reinforced plastic coating. Holz als Roh und Werkstoff 34(12): 453-458, 1976

In vitro study of fracture strength and marginal adaptation of polyethylene-fibre-reinforced-composite versus glass-fibre-reinforced-composite fixed partial dentures. Journal of Oral Rehabilitation 29(7): 668-674, 2002

Silage tower silos: capacities and silage pressures. Forage conservation in the 80' s Occasional Symposium No11 [Thomas, C Editor]: 289-293, 1980

Composites for bone repair: phosphate glass fibre reinforced PLA with varying fibre architecture. Journal of Materials Science. Materials in Medicine 22(8): 1825-1834, 2011

Response evaluation of yellow-poplar glulam beams reinforced with pultruded glass-fiber reinforced plastic. Paper er 1994 (4566 4580), 1994

Silos and fluid tanks from glass fiber reinforced polyester. Deutsche Muller Zeitung: 74 (1) 2-3, 1976

Pressures exerted by grain and silage stored in silos. 1991

Silos and flow tanks made from glass fiber reinforced polyester. Deutsche Muller Zeitung: 73 (5) 80-81, 1975

A new measuring technique for the determination of silage pressures in tower silos. Translation, National Institute of Agricultural Engineering (424): 11 pp, 1979

Silage pressures in tower silos. 1. Theoretical and design considrations. Canadian agricultural engineering: 19 (2) 92-97, 1977