Factors affecting the performance of diffused-air aeration systems for aquaculture



Factors affecting the performance of diffused-air aeration systems for aquaculture



Journal of Applied Aquaculture 2(2): 1-12



A diffused-air aeration system which operated at low gauge pressure (1.1-4.3 m H2O) was operated with 6 or 12 diffusers at 5 depths between 0.91 and 3.35 m and 6 air flow rates between 28 and 255 litres/min.

Accession: 002379993

Download citation: RISBibTeXText

DOI: 10.1300/J028v02n02_01

Download PDF Full Text: Factors affecting the performance of diffused-air aeration systems for aquaculture



Related references

The performance and design of packed column aeration systems for aquaculture. Aquacultural Engineering 1(4): 275-295, 1982

Efficiency of diffused aeration systems in waste water treatment. Journal Water Pollution Control Federation 48(10): 2273-2283, 1976

Transfer number in fine bubble diffused aeration systems. Water Science and Technology 43(11): 145-152, 2001

Bubble size and contact time in diffused aeration systems. Journal Water Pollution Control Federation 46(9): 2129-2137, 1974

Effects of impurities on oxygen transfer rates in diffused aeration systems. Water Research 35(13): 3041-3048, September, 2001

Air-water ratio as a characteristic criterion for fine bubble diffused aeration systems. Chemical Engineering Journal 137(2): 214-224, 2008

Impact of bubble and free surface oxygen transfer on diffused aeration systems. Water Research 37(8): 1890-1904, 2003

Role of hydrodynamic factors in ammonia desorption by diffused aeration. Water Research 15(6): 739-744, 1981

Evaluation of oxygen transfer efficiency and alpha factor on a variety of diffused aeration systems. Water Environment Research 64(5): 691-698, 1992

Factors influencing oxygen transfer in fine pore diffused aeration. Water Research 25(12): 1479-1486, 1991

Effect of bubble-induced surface turbulence on gas-liquid mass transfer in diffused aeration systems. Water Environment Research 77(2): 128-137, 2005

Enhancement of oxygen transfer efficiency in diffused aeration systems using liquid-film-forming apparatus. Environmental Technology 28(5): 511-519, 2007

Predicting oxygen transfer of fine bubble diffused aeration systems - model issued from dimensional analysis. Water Research Oxford 39(7): 1379-1387, 2005

Oxygen-transfer efficiency of fine-pore diffused aeration systems: energy intensity as a unifying evaluation parameter. Water Environment Research 71(4): 6-9, 1999

Oxygen-transfer efficiency of fine-pore diffused aeration systems: Energy intensity as a unifying evaluation parameter. Water Environment Research 70(3): 323-333, May-June, 1998