Intramedullary nailing of diaphyseal fractures with self-reinforced polylactide implants


Journal of Small Animal Practice 34(7): 337-344
Intramedullary nailing of diaphyseal fractures with self-reinforced polylactide implants
In fracture treatment, several adverse effects of metal, especially its excessive rigidity, often require the removal of the implants after a fracture has healed. Recent research with biodegradable polymers has contributed to the development of totally biodegradable polylactic acid implants with very high initial bending and shear strengths, but a modulus of elasticity comparable to that of bone. These implants were originally intended for use in fractures involving cancellous bone. Encouraging results from treating experimentally produced diaphyseal fractures led the authors to use these implants in a clinical trial on shaft fractures in dogs and cats. In this study, a total of 11 dogs and 14 cats had 28 diaphyseal fractures treated with one or several intramedullary pins of self-reinforced left isomeric polylactic acid. Of the 25 treated cases, 23 healed. Four of these had an unsatisfactory end result attributed to the implants used and one developed an osteomyelitis. Thus, out of 25 fractures, 23 united (92 per cent) and 18 (72 per cent) had a good or excellent outcome.

Accession: 002416163

DOI: 10.1111/j.1748-5827.1993.tb02707.x

Download PDF Full Text: Intramedullary nailing of diaphyseal fractures with self-reinforced polylactide implants



Related references

Quantification of reaming debris at the fracture gap of diaphyseal A3 femur fractures after reamed intramedullary nailing and using an intramedullary application system. Journal of Trauma 69(6): E98-101, 2011

Intramedullary nailing in diaphyseal fractures. Le Journal Medical Libanais. Lebanese Medical Journal 9(4): 538-545, 1956

Intramedullary nailing of diaphyseal fractures of the femur. Prensa Medica Argentina 43(36): 2706-2715, 1956

Intramedullary nailing in diaphyseal fractures of the femur. Afrique Francaise Chirurgicale 4: 138-142, 1950

Intramedullary nailing in diaphyseal fractures of the forearm. Archivio di Ortopedia 65(1): 83-94, 1952

Retrograde intramedullary nailing of femoral diaphyseal fractures. Journal of Orthopaedic Trauma 12(7): 464-468, 1998

Closed intramedullary nailing of diaphyseal fractures of the forearm. La Chirurgia Degli Organi di Movimento 64(4): 383-393, 1978

Reamed intramedullary nailing of diaphyseal tibial fractures: comparison of compression and non-compression nailing. European Journal of Trauma and Emergency Surgery 39(1): 73-77, 2013

Diaphyseal humeral fractures and intramedullary nailing: Can we improve outcomes?. Indian Journal of Orthopaedics 45(3): 208-215, 2011

Open intramedullary nailing in neglected femoral diaphyseal fractures. Injury 40(2): 209-212, 2010