A method for automatic collimator alignment in microdensity measurements


, : A method for automatic collimator alignment in microdensity measurements. Wood science and technology 30(2): 91-97

In microdensitometry, based on X-ray absorption technique and a "direct", "electronic" detector technique, it is usually not possible to observe the collimator and its alignment to the annual ring under investigation during the measurement. In this paper a method for automatic alignment of the collimator to the ring is described. The operating technique is based on an optimization of the resolution of the instrument at every annual ring while the collimator is rotated to the best position. The procedure has been in use a number of years and has proven itself to be efficient and reliable. The theory of operation for the procedure is described and its software structure is shown in a block diagram. Advantages and limitations of the procedure are discussed.

Accession: 002738307

DOI: 10.1007/bf00224960

Download PDF Full Text: A method for automatic collimator alignment in microdensity measurements


Submit PDF Full Text

No spam - Every submission is manually reviewed

Due to poor quality, we do not accept files from Researchgate

Submitted PDF Full Texts will always be free for everyone
(We only charge for PDFs that we need to acquire)

Select a PDF file:
Close
Close

Related references

Chojnowski, J.; Gajewski, R., 2011: An automatic method of the isocentre position verification for micromultileaf collimator based radiosurgery system. An efficient procedure has been developed using an electronic portal imaging device (EPID) and in-house written software for verification of a target simulator alignment with the radiation isocentre. A 5 mm tungsten ball is aligned to a linac iso...

Goossen, A.; Weber, G.M.; Dries, S.P.M., 2013: Automatic joint alignment measurements in pre- and post-operative long leg standing radiographs. For diagnosis or treatment assessment of knee joint osteoarthritis it is required to measure bone morphometry from radiographic images. We propose a method for automatic measurement of joint alignment from pre-operative as well as post-operative r...

Wisemann, M.B.; Nichols, T.E.; Dachille, M.A.; Mintun, M.A., 1996: Working towards an automatic and accurate method for PET-MR alignment. Journal of Nuclear Medicine 37(5 SUPPL ): 224P

Itoh, S.; Hiramatsu, N.; Iwata, A.; Yoshiya, K.; Imai, S., 2002: Measurements of cerebral blood flow by the noninvasive microsphere method with 123I-IMP and fan beam collimator: comparison with the continuous arterial blood sampling method. The noninvasive microsphere (NIMS) method quantifies cerebral blood flow with N-isopropyl-p-[123I]-iodoamphetamine (123I-IMP) without blood sampling of a patient, but when a fan beam collimator is used for collecting raw data in single photon emis...

Uchida, Koji, 2000: Automatic alignment optometric measurement apparatus and method using the same. An optometric apparatus includes a luminous flux projecting unit for projecting a luminous flux to one eye of a subject to be measured, an imaging unit for imaging an anterior part of the eye illuminated by the luminous flux projecting unit, a pos...

Nitta, S.; Takeguchi, T.; Matsumoto, N.; Kuhara, S.; Yokoyama, K.; Ishimura, R.; Nitatori, T., 2014: Automatic slice alignment method for cardiac magnetic resonance imaging. Automatic slice alignment is important for easier operation and shorter examination times in cardiac magnetic resonance imaging (MRI) examinations. We propose a new automatic slice alignment method for six cardiac planes (short-axis, vertical long...

Yokoyama, K.; Ishimura, R.; Kariyasu, T.; Imai, M.; Nitatori, T.; Kuhara, S.; Nitta, S.; Takeguchi, T.; Matsumoto, N., 2015: Clinical application of an automatic slice-alignment method for cardiac MR imaging. We evaluated the usefulness of an automatic slice-alignment method to simplify planning of cardiac magnetic resonance (MR) scans with a 3-tesla scanner. We obtained 2-dimensional (2D) axial multislice images using steady-state free precession (SSF...

Saegusa K.; Arimizu N.; Uematsu S., 1984: Evaluation of gamma camera collimator for regional cerebral blood flow measurements using xenon 133 inhalation method. In the measurements of regional cerebral blood flow (rCBF) using inhalation of 133Xe gas, the activity present is generally limited in lower levels than those of usual brain scintigraphy. Measurements with low count-rate are usually resulted in di...

Saegusa, K.; Arimizu, N.; Uematsu, S., 1984: Evaluation of gamma camera collimator for regional cerebral blood flow measurements using a 133Xe inhalation method. In the measurements of regional cerebral blood flow (rCBF) using inhalation of 133Xe gas, the activity present is generally limited in lower levels than those of usual brain scintigraphy. Measurements with low count-rate are usually resulted in di...

Cao, M.; Takaoka, A.; Zhang, H-Bo.; Nishi, R., 2011: An automatic method of detecting and tracking fiducial markers for alignment in electron tomography. We presented an automatic method for detecting and tracking colloidal gold fiducial markers for alignment in electron tomography (ET). The second-order derivative of direction was used to detect a fiducial marker accurately. The detection was opti...