A method for automatic collimator alignment in microdensity measurements


Wood science and technology 30(2): 91-97
A method for automatic collimator alignment in microdensity measurements
In microdensitometry, based on X-ray absorption technique and a "direct", "electronic" detector technique, it is usually not possible to observe the collimator and its alignment to the annual ring under investigation during the measurement. In this paper a method for automatic alignment of the collimator to the ring is described. The operating technique is based on an optimization of the resolution of the instrument at every annual ring while the collimator is rotated to the best position. The procedure has been in use a number of years and has proven itself to be efficient and reliable. The theory of operation for the procedure is described and its software structure is shown in a block diagram. Advantages and limitations of the procedure are discussed.

Accession: 002738307

DOI: 10.1007/bf00224960

Download PDF Full Text: A method for automatic collimator alignment in microdensity measurements



Related references

An automatic method of the isocentre position verification for micromultileaf collimator based radiosurgery system. Australasian Physical & Engineering Sciences in Medicine 34(1): 15-21, 2011

Automatic joint alignment measurements in pre- and post-operative long leg standing radiographs. Methods of Information in Medicine 51(5): 406-414, 2013

Working towards an automatic and accurate method for PET-MR alignment. Journal of Nuclear Medicine 37(5 SUPPL ): 224P, 1996

Measurements of cerebral blood flow by the noninvasive microsphere method with 123I-IMP and fan beam collimator: comparison with the continuous arterial blood sampling method. Kaku Igaku. Japanese Journal of Nuclear Medicine 38(6): 689-698, 2002

Automatic alignment optometric measurement apparatus and method using the same. Official Gazette of the United States Patent & Trademark Office Patents 1240(2), Nov 14, 2000

Automatic slice alignment method for cardiac magnetic resonance imaging. Magma 26(5): 451-461, 2014

Clinical application of an automatic slice-alignment method for cardiac MR imaging. Magnetic Resonance in Medical Sciences 13(4): 293-298, 2015

Evaluation of gamma camera collimator for regional cerebral blood flow measurements using xenon 133 inhalation method. Radioisotopes 33(9): 623-628, 1984

Evaluation of gamma camera collimator for regional cerebral blood flow measurements using a 133Xe inhalation method. Radioisotopes 33(9): 623-628, 1984

An automatic method of detecting and tracking fiducial markers for alignment in electron tomography. Journal of Electron Microscopy 60(1): 39-46, 2011