EurekaMag.com logo
+ Translate

The characteristic study of longitudinal-flow heat exchanger tube bank


, : The characteristic study of longitudinal-flow heat exchanger tube bank. Journal of Nanjing Forestry University 20(1): 85-89

The engineering aspects of a longitudinal-flow heat exchanger tube are presented (of relevance to kiln drying of wood).

(PDF 0-2 workdays service)

Accession: 002980168

Submit PDF Full Text: Here


Submit PDF Full Text

No spam - Every submission is manually reviewed

Due to poor quality, we do not accept files from Researchgate

Submitted PDF Full Texts will always be free for everyone
(We only charge for PDFs that we need to acquire)

Select a PDF file:
Close
Close

Related references

Zeng, W.-L.; Zhang, Z.-G., 2012: Problems involved in the shell-side performance of a longitudinal-flow shell-and-tube heat exchanger with decrease in L/D and its solutions. This paper presents a numerical simulation of the fluid flow and heat transfer in the shell-side of a large-scale shell-and-tube heat exchanger with longitudinal flow through porous-medium and distributed-resistance model. Such characteristics as...

Yanadori, M.H.mano, M., 1994: Study on the heat-flow controllable heat exchanger (2nd report): dehumidification in the greenhouse by the ventilation type dehumidifier with heat-flow controllable heat exchanger. A novel ventilation type dehumidifier with heat-flow controllable heat exchanger was installed on the wall of a greenhouse. Dehumidification and heat recovery experiments were conducted. The construction of the novel dehumidifier is simpler than t...

Yanadori, M.H.mano, M.K.wano, T., 1994: Study on the heat-flow controllable heat exchanger (1st report): thermal characteristics of heat-flow controllable heat exchanger. To regulate temperature in passive solar houses and green houses, the authors have developed a heat exchanger capable of controlling the heat flow. It has a thermal switch mechanism without mechanically moving parts. It consists of an evaporator,...

Clementi, F.; Parente, E.; Ricciardi, A.; Addario, G.; Moresi, M., 1995: Heat resistance of Escherichia coli in goat milk: A comparison between the sealed capillary tube technique and a laboratory slug flow heat exchanger. A laboratory scale two-phase (air-liquid) slug flow heat exchanger was developed to evaluate the heat resistance of Escherichia coli in goat milk. The laboratory heat exchanger allowed a stable flow to be established. Slug length, velocity and res...

Dodeja, A.K.; Sarma, S.C.; Abichandani, H., 1989: Thin film scraped surface heat exchanger and plate heat exchanger - a comparative study. Performance of thin-film scraped-surface heat exchangers (SSHE) was compared with that of plate heat exchangers (PHE) using data generated from cooling of water and milk in the SSHE to determine film coeff. which were compared with those obtained...

Ellborg, A., 1990: Thermal time distributions in a tube heat exchanger: a study with application to sterilisation of liquid foods. This study deals with the distribution of heat treatment within the flow of heat exchangers. The distribution is induced by the combined effect of velocity and temp. gradients, and is referred to as the thermal time-distribution (TTD). The TTD is...

Pereira, E.C.; Bhattacharya, M.; Morey, R.V., 1989: Modeling heat transfer to non-Newtonian fluids in a double tube heat exchanger. Transactions of the ASAE 32: 6-62

Batmaz, E.; Sandeep, K.P., 2008: Overall heat transfer coefficients and axial temperature distribution in a triple tube heat exchanger. Computation of overall heat transfer coefficients in a triple tube heat exchanger (TTHE) is more complicated than in the case of a double tube heat exchanger (DTHE) as the two overall heat transfer coefficients are not independent of one other. A...

Legay, M.; Simony, B.; Boldo, P.; Gondrexon, N.; L.P.rson, S.; Bontemps, A., 2012: Improvement of heat transfer by means of ultrasound: Application to a double-tube heat exchanger. A new kind of ultrasonically-assisted heat exchanger has been designed, built and studied. It can be seen as a vibrating heat exchanger. A comprehensive description of the overall experimental set-up is provided, i.e. of the test rig and the acqui...

Sahoo, P.; Ansari, M.; Datta, A., 2003: A computer based iterative solution for accurate estimation of heat transfer coefficients in a helical tube heat exchanger. An iterative technique is developed and reported for accurate estimation of heat transfer coefficients in a helical triple tube heat exchanger. Based on the experimental temperature rise of whole milk in a helical triple tube heat exchanger, accur...