Evaluation of the Bactoscan 8000 method for the determination of total bacterial count in raw milk



Evaluation of the Bactoscan 8000 method for the determination of total bacterial count in raw milk



Bulletin of the International Dairy Federation ( 330): 37-51



A description is given of the Bactoscan 8000 method for determination of bacterial count in raw milk. The following descriptive parameters were derived: lower and upper limits of detection 10-20 000 and >3 x 106 c.f.u./ml, respectively; precision data are dependent on the counting level; repeatability (r) and reproducibility (R) on a level of 100 Bactoscan counts (BC) were 0.06 and 0.12 log cfu/ml, respectively; the accuracy of the estimate was indicated by 0.2-0.35 log c.f.u./ml.

Please choose payment method:






(PDF emailed within 1 workday: $29.90)

Accession: 003133112

Download citation: RISBibTeXText


Related references

Total Bacterial Count in Raw Milk Using the BactoScan 8000. Journal of AOAC International 76(4): 838-841, 1993

Suitability of the Bactoscan procedure for determination of total bacterial count of raw milk. Osterreichische Milchwirtschaft 38(19): 373-384, 1983

Relationship between results obtained using the standard plate count reference method and the BactoScan 8000 automatic instrument for ewe and goat milk. Scienza e Tecnica Lattiero Casearia 46(4): 241-252, 1995

Study of the bactoscan 8000 and comparison with the plate count agar method. Alimentaria 28(220): 33-38, 1991

Study of the Bactoscan 8000 and its comparison with the agar plate count method. Alimentaria ( 220): 33-38, 1991

Suitability of the Bactoscan apparatus for determination of total cell count in raw milk. Milchwirtschaftliche Berichte aus den Bundesanstalten Wolfpassing und Rotholz (76): 211-215, 1983

Assessment of the BactoScan 8000 for rapid and automatic enumeration of total flora in raw milk. Lait Lyon 71(6): 661-670, 1991

Evaluation of the Bactoscan FC. 1. Accuracy, comparison with the Bactoscan 8000 and somatic cells effect. Milchwissenschaft 55(2): 67-70, 2000

New method for direct determination of total bacterial count of milk. Deutsche Milchwirtschaft 23(34): 1301, 1972

Simplified method for determination of total bacterial count in milk. Roczniki Instytutu Przemyslu Mleczarskiego 19(2): 9-17, 1977

Determination of the bacteriological quality of raw milk by automatic fluorescent microscopic counting of single bacteria (Bactoscan 8000) - a review. Kieler Milchwirtschaftliche Forschungsberichte 49(3): 163-186, 1997

Validation parameters of an instrumental method for determination of total bacterial count in milk. Mljekarstvo 54(4): 299-314, 2004

Evaluation of the manual plate loop method for determining the total bacterial count of refrigerated milk. South African Journal of Dairy Technology 15(1): 15-18, 1983

Suitability of Bactoscan device for determining the total germ count in raw milk. Milchwirtschaftliche Berichte aus den Bundesanstalten Wolfpassing und Rotholz: (76) 211-215, 1983

Evaluation of bulk milk quality by methylene blue and resazurin reduction tests and determination of total bacterial count. Veterinariya, Kiev, Ukrainian SSR (38): 93-97, 1974