A flow injection (FI) biosensor system for pentachlorophenol (PCP) using a substrate recycling scheme






Environmental Science and Technology 34(15): 3291-3295

A flow injection (FI) biosensor system for pentachlorophenol (PCP) using a substrate recycling scheme

A flow injection (FI) biosensor system has been designed for the analysis of pentachlorophenol (PCP) using a substrate recycling scheme comprising immobilized bilirubin oxidase (BOX) in the presence of excess of NADH. PCP was efficiently converted to tetrachloro-p-benzoquinone (1,4-TCBQ) and then tetrachloro-p-hydroquinone (1,4-TCHQ) by bis(trifluoroacetoxy)iodobenzene (BTFAIB) and zinc powder, respectively. BOX immobilized on aminopropyl glass beads rapidly oxidized 1,4-TCHQ to 1,4-TCBQ, which in turn was readily reduced back to 1,4-TCHQ in the presence of excess NADH. This recycling scheme enabled one molecule of PCP to consume several NADH molecules leading to enhanced sensitivity. Under optimized conditions the rate of NADH uptake measured as the absorbance decrease at 340 nm yielded a detection limit for 1,4-TCHQ or oxidized PCP of 250 nM. The detection limit was improved to 25 nM for both analytes using a fluorescence detector with excitation and emission wavelengths of 345 and 450 nm, respectively. The PCP level in contaminated soil samples was measured using the FI biosensor system, and the results obtained compared well with capillary zone electrophoresis (CZE) analysis. Reprinted by permission of the publisher.

Accession: 003342913

DOI: 10.1021/es0009370

Download PDF Full Text: A flow injection (FI) biosensor system for pentachlorophenol (PCP) using a substrate recycling scheme



Related references

Labra Espina, M.; Male, K.B.; Luong, J.H.T., 2000: A flow injection biosensor system for pentachlorophenol using a substrate recycling scheme. A flow injection (FI) biosensor system has been designed for the analysis of pentachlorophenol (PCP) using a substrate recycling scheme comprising immobilized bilirubin oxidase (BOX) in the presence of excess of NADH. PCP was efficiently converted...

Cybulski, D.; Male, K.B.; Scharer, J.M.; Moo Young, M.; Luong, J.H.T., 1999: Substrate recycling scheme for tetrachloro-p-benzoquinone using bilirubin oxidase and NADH: application for pentachlorophenol assay. A novel assay for tetrachloro-p-benzoquinone (TCBQ), the main oxidation product of pentachlorophenol (PCP), was developed using bilirubin oxidase (BOX) in the presence of excess NADH. TCBQ was easily and rapidly reduced by NADH to 1,4-tetrachloroh...

Yao T.; Kobayashi N.; Wasa T., 1990: Amperometric flow injection system with an immobilized enzyme reactor for the highly selective detection of phosphate and on line amplification by substrate recycling. Bio-amperometric flow-injection systems are proposed for the highly selective and sensitive determination of phosphate. One system studied is based on the use of a co-immobilized purine nucleoside phosphorylase-xanthine oxidase reactor, which resp...

Yao, T.; Ogawa, H.; Nakahara, T., 1995: Highly selective and sensitive detection of NADP coenzymes using co-immobilized glucose-6-phosphate dehydrogenase/diaphorase reactors as on-line amplifiers based on substrate recycling in a chemiluminometric flow-injection system. Two enzyme reactors prepared by the co-immobilization of two different glucose-6-phosphate dehydrogenases (G6PDH; from Leuconstoc mescenteroides (LM) and yeast (Y) and diaphorase are employed to enhance the sensitivity of NAD(P) coenzymes as on-li...

Yao T.; Kobayashi N.; Wasa T., 1990: Amperometric flow injection of analysis of l glutamate using an immobilized enzyme reactor amplification by substrate recycling. An amperometric flow injection system with an immobilized enzyme reactor that gives responses amplified by substrate recycling was employed for the higher sensitive determination of L-glutamate. An L-glutamate oxidase/glutamic-pyruvic transaminase...

Male, K.B.; Saby, C.; Luong, J.H., 1998: Optimization and characterization of a flow injection electrochemical system for pentachlorophenol assay. A flow injection (FI) electrochemical detection system was developed and optimized for the determination of pentachlorophenol (PCP) in contaminated soil. PCP was oxidized to tetrachloro-1,4-benzoquinone (1,4-TCBQ) with a high yield using bis(trifl...

Ye, B.; Li, Q.; Li, Y.; Yu, J., 1994: The glutamate biosensor and its application to flow injection analysis system. A micro-enzyme electrode was fabricated by cross-linking L-glutamate oxidase with glutaraldehyde on aminopropyl-platinized platinum wire. A flow injection analysis system with glutamate sensor was used for L-glutamate determination. The peak curre...

Yamaguchi, M.; Kanemaru, M.; Kanemori, T.; Mizuno, Y., 2003: Flow-injection-type biosensor system for salivary amylase activity. The authors aim to establish a method that can quantitatively evaluate vital reactions to stress. We have been examining the correlation between stress and salivary amylase activity in order to verify its validity as a stress index. In order to qu...

Katsu, T.; Wei, H.; Hu, W.; Zhang, X.; Zhang, X., 1995: Liposome membrane permeability assay using a glucose biosensor flow injection system. Analytical Letters 28(9): 1571-1578

Yong, D.; Liu, C.; Zhu, C.; Yu, D.; Liu, L.; Zhai, J.; Dong, S., 2016: Detecting total toxicity in water using a mediated biosensor system with flow injection. A novel total toxicity detection method based on a mediated biosensor system with flow injection (MB-FI) was developed to rapidly and reliably detect respiration inhibitors (i.e., As2O3, KCN, salicylic acid (SA), 2,4-dintirophenol (DNP)) in water....