Integration of microfabricated needle-type glucose sensor devices with a novel thin-film Ag/AgCl electrode and plasma-polymerized thin film: mass production techniques



Integration of microfabricated needle-type glucose sensor devices with a novel thin-film Ag/AgCl electrode and plasma-polymerized thin film: mass production techniques



Analyst 126(5): 658-663



We developed an integrated array of needle-type biosensors employing a novel process of fabrication, comprising conventional semiconductor fabrication and micromachining technology. Amperometric sensing electrodes with plasma-polymerized films and a thin-film Ag/AgCl reference electrode were directly integrated on a glass substrate with thin-film process, e.g., sputtering. An enzyme was immobilized on the electrode via the plasma-polymerized film, which was deposited directly on the substrate using a dry process. The novel thin-film Ag/AgCl reference electrode showed stable potentials in concentrated chloride solutions for a long period. The plasma-polymerized film is considered to play an important role as an interfacial design between the sensing electrode and the immobilized enzyme considering that the film is extremely thin, adheres well to the substrate (electrode) and has a highly cross-linked network structure and functional groups, such as amino groups. The results showed increments of the sensor signal, probably because the plasma-polymerized film allowed a large amount of enzyme to be immobilized. The greatest advantage is that the process can permit the mass production of high-quality biosensors at a low cost.

Please choose payment method:






(PDF emailed within 0-6 h: $19.90)

Accession: 003480622

Download citation: RISBibTeXText

PMID: 11394309

DOI: 10.1039/b008036p


Related references

Thin-film glucose biosensor based on plasma-polymerized film: simple design for mass production. Analytical Chemistry Washington 72(11): 2671-2675, 2000

A glucose sensor with a plasma-polymerized thin film fabricated by dry processes. Electroanalysis 11(15): 1098-1100, 1999

A novel thin-film Ag/AgCl anode structure for microfabricated Clark-type oxygen electrodes. Sensors and Actuators B: Chemical 53(3): 140-146, 1998

Amperometric glucose biosensor based on mediated electron transfer between immobilized glucose oxidase and plasma-polymerized thin film of dimethylaminomethylferrocene on sputtered gold electrode. Analytical Sciences 20(8): 1143-1146, 2004

A solid-state thin-film Ag/AgCl reference electrode coated with graphene oxide and its use in a pH sensor. Sensors 15(3): 6469-6482, 2015

A Cuprous Oxide Thin Film Non-Enzymatic Glucose Sensor Using Differential Pulse Voltammetry and Other Voltammetry Methods and a Comparison to Different Thin Film Electrodes on the Detection of Glucose in an Alkaline Solution. Biosensors 8(1):, 2018

A micromachined gas sensor based on a catalytic thick film/SnO2 thin film bilayer and thin film heater: Part 1: CH4 sensing. Sensors and Actuators B: Chemical 109(2): 185-189, 2005

A micromachined gas sensor based on a catalytic thick film/SnO2 thin film bilayer and a thin film heater: Part 2: CO sensing. Sensors and Actuators B: Chemical 109(2): 190-193, 2005

Adsorption and desorption of fab' 2 anti higg on plasma polymerized allylamine thin film the application of the film to immunoassay. Journal of Colloid and Interface Science 147(2): 378-386, 1991

Thin-film electrode based on TCNQ complex and immobilized enzyme for a glucose sensor. Sensors and Actuators B: Chemical 20(2-3): 225-230, 1994

A conductometric glucose sensor based on a twin-microband electrode coated with a polyaniline thin film. Bulletin of the Chemical Society of Japan 67(10): 2864-2866, 1994

A galactose biosensor based on the microfabricated thin film electrode. Analytical Letters 36(10): 2095-2106, 2003

Problems associated with the thin-film Ag/AgCl reference electrode and a novel structure with improved durability. Sensors and Actuators B: Chemical 46(2): 104-113, 1998

Enhancement of physical and chemical properties of thin film Ag/AgCl reference electrode using a Ni buffer layer. Sensors and Actuators B: Chemical 97(2-3): 348-354, 2004

Effect of electrode interface structure on the characteristics of a thin-film limiting current type oxygen sensor. Sensors and Actuators B: Chemical 108(1-2): 326-330, 2005