EurekaMag.com logo
+ Site Statistics
References:
53,869,633
Abstracts:
29,686,251
+ Search Articles
+ Subscribe to Site Feeds
EurekaMag Most Shared ContentMost Shared
EurekaMag PDF Full Text ContentPDF Full Text
+ PDF Full Text
Request PDF Full TextRequest PDF Full Text
+ Follow Us
Follow on FacebookFollow on Facebook
Follow on TwitterFollow on Twitter
Follow on LinkedInFollow on LinkedIn

+ Translate

Effect of evaporative cooling systems in house for poultry



Effect of evaporative cooling systems in house for poultry



Engenharia Agricola 20(2): 87-97



An experiment was carried out on February 1996 to determine the effect of evaporative cooling system on the improvement of poultry house thermal condition. The building was divided in four sectors with equal dimensions. The treatments consisted of a ventilator and spraying system; high rotation ventilator and spraying system; and spraying system and ventilator connected to the sprayer.

(PDF emailed within 1 workday: $29.90)

Accession: 003727919

Download citation: RISBibTeXText



Related references

Evaporative cooling system and method of cooling a poultry house. Official Gazette of the United States Patent & Trademark Office Patents 1235(2), June 13, 2000

Evaporative cooling system for cooling a poultry house. Official Gazette of the United States Patent & Trademark Office Patents 1235(4), June 27, 2000

The effects of evaporative cooling on climatic environment in poultry house. Proceedings of the sixth International Conference on Animal and Poultry Production held at University of Zagazig Zagazig Egypt 21-23 September 1982 Egyptian Society of Animal Production: 516, 1982

The effect of insulation level of the construction elements and evaporative cooling systems in the poultry houses on laying hen performance in hot climate. Increasing work efficiency in agriculture, horticulture and forestry XXXI CIOSTA CIGR V Congress Proceedings, Hohenheim, Germany, 19-21 September, 2005: 347-353, 2005

Development of software to design ventilation and evaporative cooling systems in climatized poultry facilities. Engenharia Na Agricultura: 2, 167-179, 2008

Effect of the systems of evaporative cooling in the performance of lactation sows and their litters. Engenharia Agricola 18(4): 1-13, 1999

Performance of evaporative cooling and spray cooling systems in a buffalo shelter. Journal of agricultural engineering 17(3-4): 19-36, 1980

Managing evaporative cooling for better poultry production. Poultry Digest 47(556): 280-282, 284, 1988

Evaporative cooling of livestock and poultry - state of the art. Paper, American Society of Agricultural Engineers (83-4022): 12 pp, 1983

Evaporative cooling in a central illinois usa swine house. Journal of Animal Science 37(1): 242, 1973

Use of evaporative cooling to reduce poultry heat stress. ASAE paper (81-4558): 26 pp, 1981

Performance characteristics of a pad evaporative cooling system in a broiler house in a Mediterranean climate. Biosystems Engineering 103(1): 100-104, 2009

Evaporative cooling reduces mortality, aids production Poultry buildings, temperatures. Poultry digest 41(483): 242-244, 1982

Field experiments and economic evaluation of an evaporative cooling system in a silkworm rearing house. Biosystems Engineering 93(2): 213-219, 2006

A comparative financial analysis of investment in broiler farming between evaporative cooling house system and open house system based on animal welfare: a case study of broiler farms in Lopburi Province. Proceedings of 43rd Kasetsart University Annual Conference, Thailand, 1-4 February, 2005 Subject: Agricultural Extension and Communication; Social Sciences; Economics; Business Administration; Humanities; Home Economics: 439-447, 2005