EurekaMag.com logo
+ Site Statistics
References:
53,869,633
Abstracts:
29,686,251
+ Search Articles
+ Subscribe to Site Feeds
EurekaMag Most Shared ContentMost Shared
EurekaMag PDF Full Text ContentPDF Full Text
+ PDF Full Text
Request PDF Full TextRequest PDF Full Text
+ Follow Us
Follow on FacebookFollow on Facebook
Follow on TwitterFollow on Twitter
Follow on LinkedInFollow on LinkedIn

+ Translate

Effect of exhaust cone tube structure on power performance of a thermal fogger



Effect of exhaust cone tube structure on power performance of a thermal fogger



Nongye Jixie Xuebao = Transactions of the Chinese Society of Agricultural Machinery 33(1): 43-46



In this paper, exhaust cone tubes with different outlet diameters of a thermal fogger for pesticide application were designed. The effects of the exhaust cone tube structure on the power performances of a fogger were investigated through testing the air pressure and the outlet velocity of the exhaust tube and determining its fuel consumption.

(PDF emailed within 1 workday: $29.90)

Accession: 003727939

Download citation: RISBibTeXText



Related references

Measuring potential thermal fogger transfer of surface pesticide residue generated from indoor fogger use: using the CDFA roller method. Interim Report II. Chemosphere 22(9-10): 975-984, 1991

Dissipation of exhaust gases from the Baltic Thermal Power Plant into the atmosphere. Izvest Akad Nauk Estonsk Ssr Ser Biol 12(4): 283-288, 1963

Basic study on an effective use of carbon dioxide in exhaust gas from thermal power plants by molecular sieve for vegetable production. Denryoku Chuo Kenkyusho Hokoku (486015): 1-14, 1986

A case study for removal of sulphur-di-oxide from exhaust flue gases at thermal power plant, Rajasthan (India). Journal of Environmental Science & Engineering 53(1): 31-38, 2012

Application of thermal fogger to the control of maize diseases and pests. Journal Of Anhui Agricultural University: 1, 71-74, 2010

Effect of thermal power effluents on the community structure and primary production of phytoplankton. Environment International. : 79-90, 1993

Sensitivity improvement of ammonia determination based on flow-injection indophenol spectrophotometry with manganese(II) ion as a catalyst and analysis of exhaust gas of thermal power plant. Analytical Sciences 18(10): 1141-1144, 2002

Evaluation of synthetic pyrethroids through a thermal fogger for control of house flies. International Pest Control 16(3): 4-7, 11, 1974

Loss of mTOR signaling affects cone function, cone structure and expression of cone specific proteins without affecting cone survival. Experimental Eye Research 135: 1-13, 2015

Cone-in-cone structure in siliciclastic depositional environment; new observations on the cone-in-cone of the Lower Ordovician Montagne Noire, southern French Central Massif. Geologie de la France 1990(2): 11-20, 1990

Evaluation of baygon osc and riddex 65 20 applied with the london fogger 500 thermal atomizer against adult culicids. Annales de la Societe Entomologique du Quebec 20(2): 111, 1975

Experimental modeling of the effect of relative thermal power on the shape of a plume conduit and the structure of free-convection flow in it. Russian Geology and Geophysics 53(7), 2012

Control of teak defoliator, Hyblaea puera Cramer (Lepidoptera: Hyblaeidae), by thermal fogger application of neem extract. FORSPA Publication (30): 123-125, 2002

Evaluation of a new formulation of permethrin applied by water-based thermal fogger against Aedes albopictus in residential communities in St. Augustine, Florida. Journal of the American Mosquito Control Association 29(1): 49-53, 2013

Performance Investigation of a Hospital-grade X-ray Tube-based Differential Phase-contrast Cone Beam CT System. Proceedings of Spie--the International Society for Optical Engineering 8313: -, 2012