Evaporative cooling efficiency of a fogging system for greenhouses






Turkish Journal of Agriculture and Forestry 27(1): 49-57

Evaporative cooling efficiency of a fogging system for greenhouses

The objective of this study was to investigate the efficiency of fogging system (FS) for greenhouses located in Cukurova region, Yenice-Adana, Turkey. The experiments were carried out in a multi-span plastic greenhouse (PG), 105.6 m wide and 205 m long, made of 11 spans. The FS consists of a water softener and filters to prevent nozzle clogging, a water reservoir, pumps and a pressure regulator, and fog generating nozzles (FGN). The required pressure for FGN was 4.5 atm.


Accession: 003761831



Related references

Handarto ; Hayashi, M.; Kozai, T., 2005: Air and leaf temperatures and relative humidity in a naturally ventilated single-span greenhouse with a fogging system for cooling and its evaporative cooling efficiency. Dry bulb (or air) temperature, leaf temperature of tomato plant (Tleaf), and relative humidity were measured under various fogging times (tf) around midday in summer inside a naturally ventilated single-span experimental greenhouse with a fogging...

Ozturk, H.H., 2006: Evaporative cooling efficiency of a fogging system in a rose greenhouse. The objective of this study was to investigate the effect of a fogging system on the microclimate of a rose greenhouse. The experiments were carried out in a multi-span plastic greenhouse, 106 wide by 205 m long, made of 11 spans. The fogging syst...

Abdel-Ghany, A.; Kozai, T., 2006: Cooling Efficiency of Fogging Systems for Greenhouses. The cooling efficiency (Sj(Bc of wet pad and fan systems, which is currently used for fogging systems, is defined assuming that the dry bulb temperature in the greenhouse Tdb,i is lower than the outside dry bulb temperature Tdb,o and is measured d...

Abdel-Ghany, A., M.; Kozai, T., 2007: Concept of the un-cooled air in a greenhouse cooled by fogging in summer: An aid to estimate the cooling efficiency of a fogging system. The current definition of the evaporative cooling efficiency (27.) can be applied only for a greenhouse with a wet pad-fan system, in which no sensible or latent heat is added to the air during the cooling process. However, q. of the wet pad-fan...

Montero, Ji, 2006: Evaporative cooling in greenhouses: effect on microclimate, water use efficiency and plant respons. Evaporative cooling occurs as a result of the conversion of sensible heat into latent heat in mechanically supplied evaporated water. This article presents results from models based on energy and mass conservation to study the interaction between...

Montero, J.I., 2006: Evaporative cooling in greenhouses: effect on microclimate, water use efficiency and plant response. Evaporative cooling occurs as a result of the conversion of sensible heat into latent heat in mechanically supplied evaporated water. This article presents results from models based on energy and mass conservation to study the interaction between...

Egiazarov, A.G.; Pokhvalitii, A.P., 1986: A system of aerosol evaporative cooling in greenhouses. Graphical analysis was used to show how evaporative cooling systems may be controlled to take account of such variables as insolation and presence and amount of biomass. In particular, the relationship between cooling system regime and plant adapt...

Tesi, R., 1974: Effects of the evaporative cooling system in greenhouses used for roses and carnations. Roses (cv. Super Star on R. indica major and R. canina) and carnations (cv. Super Cardinal) were grown in a glasshouse (A), in a plastic house (B) provided with a cooling system, and in an uncooled plastic house (C). Cooling was provided by humidi...

Sapounas,A.A.; Nikita-Martzopoulou,C.; Bartzanas,T.; Kittas,C., 2008: Fan and pad evaporative cooling system for greenhouses evaluation of a numerical and analytical model. An experimental greenhouse equipped with fan and pad evaporative cooling was analysed using two different models. The first one consisted of a numerical simulation approach applying a commercial computational fluid dynamics (CFD) code. The main as...

Wilson, J.L.; Hughes, H.A.; Weaver, W.D., 1983: Evaporative cooling with fogging nozzles in broiler houses. Two broiler houses were equipped with high pressure fogging-type evaporative cooling equipment. It was found that the 2 systems, with different nozzle mounting arrangements, could lower dry-bulb temperature in the houses by 3.3 to 4.4 deg C. When...