+ Site Statistics
+ Search Articles
+ PDF Full Text Service
How our service works
Request PDF Full Text
+ Follow Us
Follow on Facebook
Follow on Twitter
Follow on LinkedIn
+ Subscribe to Site Feeds
Most Shared
PDF Full Text
+ Translate
+ Recently Requested

Simultaneous measurement of gastric emptying with a simple muffin meal using octanoate breath test and scintigraphy in normal subjects and patients with dyspeptic symptoms



Simultaneous measurement of gastric emptying with a simple muffin meal using octanoate breath test and scintigraphy in normal subjects and patients with dyspeptic symptoms



Digestive Diseases and Sciences 47(7): 1657-1663



The objective of this study was to determine how the [13C]octanoate breath test (OBT) using a muffin meal correlates with gastric emptying scintigraphy (GES) in normal subjects and patients with dyspeptic symptoms. Ten normal subjects and 23 patients with dyspeptic symptoms underwent simultaneous GES and [13C]OBT. After an overnight fast, a muffin labeled with [99mTc]-sulfur colloid and [13C]octanoate was ingested along with water labeled with [111In]DTPA. Breath samples and scintigraphic images were obtained at baseline and at regular postprandial intervals over 6 hr. In the normal subjects, the mean GES 71/2 of solids and liquids were 64 +/- 17 and 55 +/- 27 minutes, respectively. The calculated OBT T1/2 using the 6-hr breath collection was 138 +/- 15 min and correlated with T1/2 for solids by GES (r = 0.664; P = 0.051), but did not correlate with T1/2 for liquids by GES (r = 0.13; P = 0.738). In dyspeptic patients, the T1/2 for GES was 87 +/- 53 min and 81 +/- 70 min for solids and liquids, respectively. The mean OBT T1/2 was 155 +/- 57 min and correlated with GES T1/2 for solids (r = 0.86; P < 0.001) and GES T1/2 for liquids (r = 0.73; P < 0.001). Delayed gastric emptying (GE) of the muffin meal was identified by scintigraphy in seven patients. The sensitivity and specificity for OBT identifying delayed GE were 86% and 94%. Use of the initial truncated 4-hr OBT results also revealed a significant correlation between OBT and GES T1/2 for solids (r = 0.86; P < 0.001) with sensitivity and specificity for detecting delayed GE of 86% and 94%, respectively. In addition, a linear regression model was able to reduce the number of collection points to four, while maintaining the same sensitivity and specificity. In conclusion, the OBT for GE, using an easily prepared muffin meal, significantly correlates with GES for solids. This muffin-based OBT is a sensitive and specific method to detect delayed GE in dyspeptic patients.

Please choose payment method:






(PDF emailed within 0-6 h: $19.90)

Accession: 003934956

Download citation: RISBibTeXText

PMID: 12141833

DOI: 10.1023/a:1015856211261


Related references

Effect of meal size and test duration on gastric emptying and gastric myoelectrical activity as determined with simultaneous [13C]octanoate breath test and electrogastrography in normal subjects using a muffin meal. Digestive Diseases and Sciences 46(12): 2643-2650, 2001

Effect of meal size and test duration on gastric emptying as determined by breath test in normal subjects using a muffin meal labeled with 13C-sodium octanoate. Gastroenterology 118(4 Suppl 2 Part 1): AGA A143, 2000

Gastric emptying characteristics of a novel muffin meal Comparison of 13C-octanoate breath testing and scintigraphy. Gastroenterology 116(4 Part 2): A971, 1999

Simultaneous 13C/14C dual isotope breath test measurement of gastric emptying of solid and liquid in normal subjects and patients: comparison with scintigraphy. Nuclear Medicine Review. Central and Eastern Europe 6(1): 29-33, 2003

Measurement of solid phase gastric emptying with a simplified muffin meal using breath testing with either 13C-octanoate or 13C-acetate. Gastroenterology 120(5 Suppl. 1): A 466, 2001

Gastric emptying measurement of liquid nutrients using the (13)C-octanoate breath test in critically ill patients: a comparison with scintigraphy. Intensive Care Medicine 39(7): 1238-1246, 2013

Measurement of gastric emptying by the 13C-octanoate breath test--rationalization with scintigraphy. Physiological Measurement 27(3): 279-289, 2006

Delayed gastric emptying of a solid and a liquid test meal in patients with idiopathic parkinsons disease by using a non invasive 13c octanoate breath test and 13c acetate breath test. Digestive Disease Week Abstracts & Itinerary Planner : Abstract No W1466, 2003

Comparison of continuous breath test and gastric scintigraphy for the measurement of gastric emptying rate in healthy and dyspeptic individuals. European Journal of Gastroenterology and Hepatology 25(3): 291-295, 2013

Impaired gastric emptying of a solid test meal in patients with Parkinson's disease using 13C-sodium octanoate breath test. Neuroscience Letters 375(3): 170-173, 2005

Gastric emptying of BIPS in normal dogs with simultaneous solid-phase gastric emptying of a test meal measured by nuclear scintigraphy. Veterinary Radiology and Ultrasound 41(4): 381-383, 2000

Gastric emptying characteristics of a novel (13)C-octanoate-labeled muffin meal. Journal of Clinical Gastroenterology 32(5): 394-399, 2001

Clinical evaluation of real time ultrasonic scanning in the measurement of gastric emptying in normal subjects and dyspeptic patients. Italian Journal of Gastroenterology 19(6): 317-320, 1987

Noninvasive carbon-13 acetate breath test for measuring gastric emptying Validation by simultaneous technetium-99m functional scintigraphy and carbon-13 dioxide breath test in double tracer technique. Gastroenterology 104(4 Suppl. ): A481, 1993

Gastric emptying assessment of solid meal by 14C-octanoic acid breath test and scintigraphy with 99Mtechnetium. Gastroenterology 114(4 Part 2): A839, 1998