EurekaMag
+ Translate
+ Most Popular
The pigeon tick (Argas reflexus): its biology, ecology, and epidemiological aspects
Prevalence of hemoglobin abnormalities in Kebili (Tunisian South)
Lipogranuloma: a preventable complication of dacryocystorhinostomy
Value of basal plasma cortisol assays in the assessment of pituitary-adrenal insufficiency
Bees from the Belgian Congo. The acraensis group of Anthophora
Placing gingival retraction cord
Total serum IgE, allergy skin testing, and the radioallergosorbent test for the diagnosis of allergy in asthmatic children
Acariens plumicoles Analgesoidea parasites des oiseaux du Maroc
Injuries of terminal phalanges of the fingers in children
Biology of flowering and nectar production in pear (Pyrus communis)
Das Reliktvorkommen der Aspisviper (Vipera aspis L.) im Schwarzwald
Hydrological modelling of drained blanket peatland
Pathologic morphology and clinical significance of the anomalous origin of the left circumflex coronary artery from the right coronary artery. General review and autopsy analysis of 30 cases
Cyto genetic analyses of lymphocyte cultures after exposure to calcium cyclamate
Axelrodia riesei, a new characoid fish from Upper Rio Meta in Colombia With remarks concerning the genus Axelrodia and description of a similar, sympatric, Hyphessobrycon-species
Favorable evolution of a case of tuberculosis of pancreas under antibiotic action
RIFM fragrance ingredient safety assessment, Valencene, CAS Registry Number 4630-07-3
Parenteral microemulsions: an overview
Temperate pasture: management for grazing and conservation
Evaluation of a new coprocessed compound based on lactose and maize starch for tablet formulation
Thermal expansion and cracking of three confined water-saturated igneous rocks to 800C
Revision of the genera of the tribe Stigmoderini (Coleoptera: Buprestidae) a discussion of phylogenetic relationships
Anal tuberculosis. Report of a case
Gastric tuberculosis in the past and present
Adaptive responses of the cardiovascular system to prolonged spaceflight conditions: assessment with Holter monitoring

Data collection and analysis from a respiratory inductance plethysmograph


Data collection and analysis from a respiratory inductance plethysmograph



International Journal of Clinical Monitoring and Computing 4(4): 237-241



ISSN/ISBN: 0167-9945

PMID: 3681107

DOI: 10.1007/bf02915864

A respiratory inductance plethysmograph, Respitrace, was used to assess the respiratory effects of narcotic analgesia for the first 24 hours after surgery. Data were collected on-line from the plethysmograph with an Apple ][+ microcomputer and stored on disc for late analysis of respiratory rates and tidal volumes, and also periods of central or obstructive apnoea using the difference in phase angle between the abdominal and respiratory components. This involved the measurement of, on average, more than 20,000 breaths per patient and techniques of data compression were required to store this amount of information on a single floppy disc. Frequent nursing interventions reduced the accuracy of tidal volume and phase angle measurements, but respiratory rates were obtained accurately breath by breath.

Please choose payment method:






(PDF emailed within 0-6 h: $19.90)

Accession: 005091345

Download citation: RISBibTeXText

Related references

Calibration of respiratory inductance plethysmograph in preterm infants with different respiratory conditions. Pediatric Pulmonology 43(11): 1135-1141, 2008

SinglePosture Calibration of the Respiratory Inductance Plethysmograph. Clinical Science 65(3): 52p.1-52p, 1983

Respiratory inductance plethysmography with an electrical impedance plethysmograph. Medical and Biological Engineering and Computing 26(2): 213-217, 1988

Single-position calibration of the respiratory inductance plethysmograph. Journal of Applied Physiology: Respiratory Environmental and Exercise Physiology 55(3): 1031-1034, 1983

Temperature sensitivity and gain stability of the respiratory inductance plethysmograph. Biological Psychology: 194, 1986

Comparison of the stability of the respiratory inductance plethysmograph vs mercury strain gauges in measuring ventilation. American Review Of Respiratory Disease Suppl.: A82, 1984

Automated, real-time calibration of the respiratory inductance plethysmograph and its application in newborn infants. Physiological Measurement 24(1): 149-163, 2003

Postural changes in rib cage and abdominal volume-motion coefficients and their effect on the calibration of a respiratory inductance plethysmograph. American Review of Respiratory Disease 127(2): 209-214, 1983

The effect of humidified air in mild to moderate croup Evaluation using croup scores and respiratory inductance plethysmograph. Pediatric Research 49(4 Part 2): 79A, 2001

Measurement of tidal volumes in premature infants using the inductance plethysmograph. Pediatric Research 19(4 Part 2): 417A, 1985

Is the respiratory inductive plethysmograph a good plethysmograph?. European Respiratory Journal 7(Suppl. 18): 37S, 1994

Respiratory distress in the neonate: Case definition & guidelines for data collection, analysis, and presentation of maternal immunization safety data. Vaccine 35(48 Pt A): 6506-6517, 2017

A Simple Numerical Analysis of Whole-Body Plethysmograph Data. Clinical Science 59(3): 29p.2-29p, 1980

Detection of movement artifacts in respiratory inductance plethysmography: performance analysis of a Neyman-Pearson energy-based detector. Conference Proceedings: .. Annual International Conference of the IEEE Engineering in Medicine and Biology Society. IEEE Engineering in Medicine and Biology Society. Annual Conference 2006: 49-52, 2004

Postthoracotomy respiratory muscle mechanics during incentive spirometry using respiratory inductance plethysmography. Chest 101(2): 432-436, 1992