Electroretinogram as a possible monitor of anesthetic depth


, : Electroretinogram as a possible monitor of anesthetic depth. Graefe's Archive for Clinical & Experimental Ophthalmology 224(5): 473-476

The effects of volatile anesthetics, i.e., methoxyflurane, halothane and enflurane, on the electroretinogram (ERG) were studied in 15 albino rabbits. The ERG was analyzed in terms of the a-wave, and the first oscillatory component (01) in the b-wave. The 01 peak latency showed a significant dose-related prolongation when anesthetic end-tidal concentrations were in excess of 0.8 minimum alveolar concentration (MAC). One MAC, a measure of anesthetic potency, is the end-tidal concentration of an anesthetic at 1 atmosphere that induces immobility in 50% of animals against a noxious stimulus. The amplitudes of the a-wave and the 01 decreased in dose-dependent manners, but their changes were less striking than those of the 01 latency. The peak latency of the a-wave remained unchanged. We conclude that the 01 peak latency is a useful monitor of the depth of inhalational anesthesia.

Accession: 005349940

PMID: 3758695

DOI: 10.1007/bf02173367

Download PDF Full Text: Electroretinogram as a possible monitor of anesthetic depth


Submit PDF Full Text

No spam - Every submission is manually reviewed

Due to poor quality, we do not accept files from Researchgate

Submitted PDF Full Texts will always be free for everyone
(We only charge for PDFs that we need to acquire)

Select a PDF file:
Close
Close

Related references

Tsutsumi, Y.; Tsuda, H., 2001: Anesthetic-depth monitor apparatus. An apparatus for monitoring an anesthetic depth of a living subject, including at least two devices of (a) an arousal-index determining device which determines an arousal index indicating a degree of arousal of the subject, (b) a pain-index determ...

Baba K.; Kitani Y.; Fujita T., 1984: Monitoring of the anesthetic depth by anesthesia and brain monitor. Japanese Journal of Anesthesiology 33(11 SUPPL): S205, S212, 11

Muzi, M.; Ebert, T.J., 1993: Can the amount of heart rate variability be used as a monitor of anesthetic depth?. Anesthesiology (Hagerstown) 79(3A): A1241

Otto, K.; Short, C.E., 1991: Electroencephalographic power spectrum analysis as a monitor of anesthetic depth in horses. Electroencephalographic (EEG) power spectrum analysis was performed in 18 conscious, adult horses for evaluation as control values for EEG data obtained during anesthesia. Computer-processed total amplitudes for the frequency range 0 to 32 Hz were...

March, P.A.; Muir, W.W., 2003: Use of the bispectral index as a monitor of anesthetic depth in cats anesthetized with isoflurane. Objective--To determine whether the prestimulation bispectral index (BIS) value or relative change in BIS after noxious stimulation can be used to assess the depth of isoflurane anesthesia in cats. Animals--17 healthy female cats. Procedure--Elect...

Alkire, M.T.; Pomfrett, C.J.D., 1996: Toward the fundamental unit of anesthetic depth Positron emission tomography suggests that bispectral index monitors an important component of anesthetic depth. Anesthesiology (Hagerstown) 85(3A): A174

Circeo, L.; Grow, D.; Kashikar, A.; Gibson, C., 2011: Prospective, observational study of the depth of anesthesia during oocyte retrieval using a total intravenous anesthetic technique and the Bispectral index monitor. Fifty patients scheduled to undergo IVF received a standard anesthetic of fentanyl and propofol for induction, followed by propofol infusion, with Bispectral index values and modified Ramsey sedation scores recorded at 5-minute intervals for the d...

Ambrisko, T.D.; Klide, A.M., 2012: Comparison of use of an infrared anesthetic gas monitor and refractometry for measurement of anesthetic agent concentrations. To assess agreement between anesthetic agent concentrations measured by use of an infrared anesthetic gas monitor (IAGM) and refractometry. SAMPLE-4 IAGMs of the same type and 1 refractometer. Mixtures of oxygen and isoflurane, sevoflurane, desflu...

Nishioka, K.; Hoshi, K.; Takahashi, S., 1987: Evaluation of anesthetic vaporizers: application of the Normac infrared anesthetic agent monitor AA 102. Masui. Japanese Journal of Anesthesiology 36(5): 778-783

Nishioka K.; Hoshi K.; Takahashi S., 1987: Evaluation of anesthetic vaporizers application of normac ir anesthetic agent monitor aa 102. In this study, twenty-two halothane vaporizers and twenty-one enflurane vaporizers of various manufacturers were evaluated for the accuracy of vaporization measuring the output by NORMAC AA 102 with step-wise increase of dial setting of vaporizer...