Evaluation of a modified acetylene rebreathing method for the determination of cardiac output

, : Evaluation of a modified acetylene rebreathing method for the determination of cardiac output. Clinical Physiology (Oxford) 6(3): 253-268

In order to evaluate a computerized modified acetylene rebreathing method for the determination of cardiac output, 15 healthy subjects were studied at different levels of their maximal oxygen uptake (.ovrhdot.VO2max). Submaximal exercise was performed on a cycle ergometer and maximal exercise on a treadmill. Oxygen uptake, heart rate, and cardiac output (acetylene method) were determined in all test situations. In seven subjects simultaneous determinations of cardiac output were made by a modified acetylene rebreathing method (.ovrhdot.QA) and a dye dilution method (.ovrhdot.QD). Furthermore, a new resting rebreathing technique was used. The methodological error for .ovrhdot.QA (means of double samples) was 0.37 litre min-1 (2.8%) in the same individual at 150 W. The corresponding values between individuals were 0.71 (rest), 0.41 (50 W), 0.69 (150 W), and 0.40 litre min-1 (.ovrhdot.VO2max). Thus the methodological error of the modified acetylene method was very low. There was a significant difference (P < 0.01), however, between the acetylene method and the dye dilution method, which showed a lower value for .ovrhdot.QA at all levels. This was probably due to the long response time of the mass spectrometer combined with anatomical and physiological arteriovenous shunt effects in the lungs during exercise. When these factors were considered the correcting formula was: .ovrhdot.QAc = .ovrhdot.QA + 0.005 .**GRAPHIC**. There was no significant difference between the corrected cardiac output values (.ovrhdot.QAc), and the corresponding .ovrhdot.QD values. In conclusion, this modified acetylene rebreathing method is a very useful non-invasive method for measuring cardiac output at rest as well as during heavy exercise.

Accession: 005395264

PMID: 3522058

DOI: 10.1111/j.1475-097x.1986.tb00623.x

Download PDF Full Text: Evaluation of a modified acetylene rebreathing method for the determination of cardiac output

Submit PDF Full Text

No spam - Every submission is manually reviewed

Due to poor quality, we do not accept files from Researchgate

Submitted PDF Full Texts will always be free for everyone
(We only charge for PDFs that we need to acquire)

Select a PDF file:

Related references

Triebwasser, J.H.; Johnson, R.L.; Burpo, R.P.; Campbell, J.C.; Reardon, W.C.; Blomqvist, C.G., 1977: Noninvasive determination of cardiac output by a modified acetylene rebreathing procedure utilizing mass spectrometer measurements. A modified acetylene rebreathing technique for measuring cardiac output has been developed utilizing a mass spectrometer for measuring gas concentrations. Helium serves as an indicator of mixing and system volume. The disappearance rate of acetyle...

Hoeper, M.M.; Maier, R.; Tongers, J.; Niedermeyer, J.; Hohlfeld, J.M.; Hamm, M.; Fabel, H., 1999: Determination of cardiac output by the Fick method, thermodilution, and acetylene rebreathing in pulmonary hypertension. Assessment of cardiac output is an important part of the management of patients with pulmonary hypertension. The accuracy of the thermodilution technique in patients with low cardiac output or severe tricuspid regurgitation has been questioned. To...

Nielsen O.W.; Hansen S.; Christensen P.; Gronlund J., 1990: Repeatability of the acetylene rebreathing method in measuring cardiac output influence of acetylene concentration. The acetylene rebreathing method is a reliable noninvasive method for estimation of cardiac output. However, the method is not commonly used for clinical purposes. This is due mainly to the fact that acetylene is explosive at concentrations above...

Wcisło, W., 2014: A modified acetylene method of determination of the cardiac output of man. Bulletin International de L'academie Polonaise des Sciences et des Lettres. Classe de Medecine 1(10): 151-168

Pugh, L.G., 1972: A modified acetylene method for the determination of cardiac output during muscular exercise. Ergonomics 15(3): 323-335

Liu, Y.; Menold, E.; Dullenkopf, A.; Reissnecker, S.; Lormes, W.; Lehmann, M.; Steinacker, J.M., 1997: Validation of the acetylene rebreathing method for measurement of cardiac output at rest and during high-intensity exercise. The use of the acetylene rebreathing method to estimate cardiac output (CO) during high-intensity exercise, which may be influenced by recirculation of acetylene, has not been validated. This study was designed to validate the acetylene rebreathin...

Jopling, M.W., 1998: Noninvasive cardiac output determination utilizing the method of partial CO2 rebreathing A comparison with continuous and bolus thermodilution cardiac output. Anesthesiology (Hagerstown) 89(3A): A544, Sept

Jernerus, R.; Lundin, G.; Pugh, L.G., 1963: Solubility Of Acetylene In Lung Tissue As An Error In Cardiac Output Determination With The Acetylene Method. The solubility of acetylene in lung tissue is measured by a rebreathing technique. Enough acetylene is dissolved in the lung tissue to simulate an extra gaseous lung between 0.27-0.48 litres. This should give an error of 7-12% in cardiac output de...

Simmons, R.; Shephard, R.J., 1971: Measurements of cardiac output in maximum exercise. Application of an acetylene rebreathing method to arm and leg exercise. Internationale Zeitschrift für Angewandte Physiologie, Einschliesslich Arbeitsphysiologie 29(2): 159-172

Hansen, S.; Wendelboe, O.; Christensen, P., 1997: The non-invasive acetylene rebreathing method for estimation of cardiac output: influence of breath-by-breath variation. The inert gas rebreathing method enables non-invasive estimation of pulmonary capillary blood flow, lung tissue volume, transfer factor and functional residual capacity. In the present study, we have examined the influence of breathing pattern dur...