Evaluation of a new ammonia sampling and analytical procedure


American Industrial Hygiene Association Journal 47(2): 135-137
Evaluation of a new ammonia sampling and analytical procedure
A new monitoring procedure is described for the collection of ammonia in the workplace environment. Sampling is conducted using air sampling tubes packed with beaded activated carbon coated with sulfuric acid. The low cationic background of this packing permits the analysis of samples to be performed by ion chromatography, a technique which offers considerable advantage over current methods used to analyze industrial hygiene samples for ammonia. Excellent precision and accuracy are demonstrated on samples collected from atmospheres containing 0.5, 1 and 2 times TLV levels of ammonia. The analytical detection limit is such that a concentration 0.05 of TLV may be detected in a 3-L air sample with less than one percent breakthrough found in a 24-L sample at TLV.


Accession: 005395319

PMID: 3953422

DOI: 10.1080/15298668691389450



Related references

A sampling and analytical procedure for skin-contamination evaluation. American Industrial Hygiene Association Journal 43(7): 473-476, 1982

Analytical performance criteria. Field evaluation of diacetyl sampling and analytical methods. Journal of Occupational and Environmental Hygiene 5(11): D111-D116, 2008

The determination of total nitrogen in sewage as ammonia without distillation and the automation of the analytical procedure. Husmann, Wilhelm (Ed ) Vom Wasser, Band 46 (On Water, Vol 46 ) (In Ger ) 296p Illus Verlag Chemie: Weinheim, West Germany Isbn 3-527-25663-6 11-20, 1976

Development of sampling and analytical procedure for for determining hexacholorobenzene and hexachloro-1,3-butadiene in air. 1974

A charcoal sampling method and a gas chromatographic analytical procedure for carbon disulfide. American Industrial Hygiene Association Journal 36(8): 618-625, 1975

A solid sorbent air sampling and analytical procedure for methylamine dimethylamine ethylamine and diethylamine. American Industrial Hygiene Association Journal 47(1): 41-49, 1986

A solid sorbent air sampling and analytical procedure for methyl-, dimethyl-, ethyl-, and diethylamine. American Industrial Hygiene Association Journal 47(1): 41-49, 1986

Time distribution of solvent vapors in a workplace sampling and analytical proposed procedure. Giornale Italiano di Medicina del Lavoro 3(1): 5-10, 1981

Successive sampling of fumarolic gases at Satsuma-Iwojima and Kuju volcanoes, Southwest Japan; evaluation of short-term variations and precision of the gas sampling and analytical techniques. Geochemical Journal 36(1): 1-20, 2002

Effect of temperature, duration of storage and sampling procedure on ammonia concentration in equine blood plasma. European Journal of Clinical Chemistry and Clinical Biochemistry 31(7): 473-476, 1993