Evaluation of a new inhibitor test for isoamylase on hitachi 705 analyzer


, : Evaluation of a new inhibitor test for isoamylase on hitachi 705 analyzer. Journal of Clinical Chemistry & Clinical Biochemistry 24(11): 903-905

We describe a simple and rapid method for measuring pancreatic and salivary type amylases using the Hitachi 705 analyzer. The determination is based on the inhibition of salivary amylase using an inhibitor isolated from wheat germ. The precision of the proposed method was very good; within-day precision varied from 0.4 to 2.5% (CV) and day-to-day precision from 2.2 to 3.7% (CV). The new application correlated well with another commercially available inhibition method. As the standardization is very stable and the assay procedure exactly the same as for the total amylase assay, the proposed method is suitable for routine isoamylase determination. Reference values for pancreatic and salivary amylase activities are presented.

(PDF 0-2 workdays service)

Accession: 005395382

PMID: 3806018

Submit PDF Full Text: Here


Submit PDF Full Text

No spam - Every submission is manually reviewed

Due to poor quality, we do not accept files from Researchgate

Submitted PDF Full Texts will always be free for everyone
(We only charge for PDFs that we need to acquire)

Select a PDF file:
Close
Close

Related references

Harmoinen, A.; Jokela, H.; Koivula, T.; Poppe, W., 1986: Evaluation of a new inhibitor test for isoamylase on Hitachi 705 analyser. We describe a simple and rapid method for measuring pancreatic and salivary type amylases using the Hitachi 705 analyser. The determination is based on the inhibition of salivary amylase using an inhibitor isolated from wheat germ. The precision o...

Parviainen, M.T.; Koivula, T.; Jokela, H., 1984: Serum amylase and isoamylase assay on the Hitachi 705 automatic clinical chemical analyzer. The automated continuous alpha-amylase assay using p-nitrophenyl-alpha-D-maltoheptaoside (Boehringer Mannheim) as substrate on the Hitachi 705 clinical chemical analyzer, was compared with the Phadebas Kinetic Amylase Assay (Pharmacia Diagnostics)...

Hubbuch A.; Tensierowski G.; Lill H., 1990: Performance of a chromogenic at iii test on a hitachi 717 analyzer. Blut 60(2): 114

Chow, L.M.; Callery, J.; Booker, C.; Couch, H.; Wong, S.S., 1993: Evaluation of the BM/Hitachi 911 analyzer. Clinical Chemistry 39(6): 1212

Wong C.; Wiedemann T.; Thomas R.; Sohmer P.; Olsen D., 1988: Evaluation of hitachi 736 analyzer. Clinical Chemistry 34(6): 1193

Chow L.M.; Johnson M.; Wong S.S.; W.A.H.B., 1992: Evaluation of the bm hitachi 747 200 analyzer. Clinical Chemistry 38(6): 1042

Mancari S.D.; Rowland S.A.; Gibbons A.B.; Kubasik N.P.; Mayer T.K.; D'souza J.P., 1990: Evaluation of the hitachi 717 analyzer. Clinical Chemistry 36(6): 1196

Douville P., 1982: Evaluation of the automatic analyzer hitachi 705. Clinical Biochemistry: 99-100

Lentjes, E.G.; Harff, G.A.; Backer, E.T., 1987: Evaluation of the Hitachi 704 automatic analyzer. We evaluated the analytical performance of the Hitachi 704 automatic analyzer. The spectrophotometer showed a linearity of response at 340 nm up to 2.8 A. Photometric imprecision measured bichromatically at 340 and 376 nm was 0.49% at 0.16 A, 0.14...

Schotters S.B.; Mcbride J.H.; Rodgerson D.O.; Mcginley M.H.; Pisa M., 1989: Evaluation of hitachi 736 chemistry analyzer. Clinical Chemistry 35(6): 1109