Evaluation of a new reusable electrode for continuous monitoring of blood oxygen tension during open heart surgery


, : Evaluation of a new reusable electrode for continuous monitoring of blood oxygen tension during open heart surgery. Journal of Medical Engineering & Technology 9(4): 174-179

In 46 patients undergoing cardiac surgery blood PO2 [O2 tension] was continuously monitored with an in-line O2 electrode during cardiopulmonary bypass and readings were compared with intermittent measurements of samples on a blood gas analyzer. In 35 patients in whom arterial PO2 was monitored, there were rapid changes in PO2 and the mean difference between the in-line electrode and the blood gas analyzer was 6.63 kPa [paschal] (P < 0.001). Venous PO2 was monitored in 11 patients and, in contrast to the arterial readings, the venous PO2 was relatively stable. The mean difference between the in-line electrode readings and the blood gas analyzer was 0.21 kPa (P < 0.05). The advantages of continuous monitoring of blood PO2 are described, and the relative merits of mixed venous PO2 and mixed venous O2 saturation measurements are discussed.


Accession: 005395428

Submit PDF Full Text: Here


Submit PDF Full Text

No spam - Every submission is manually reviewed

Due to poor quality, we do not accept files from Researchgate

Submitted PDF Full Texts will always be free for everyone
(We only charge for PDFs that we need to acquire)

Select a PDF file:
Close
Close

Related references

Claremont, D.J.; Pagdin, T.M., 1985: Evaluation of a new re-usable electrode for continuous monitoring of blood PO2 during open-heart surgery. In 46 patients undergoing cardiac surgery blood PO2 was continuously monitored with an in-line oxygen electrode during cardiopulmonary bypass and readings were compared with intermittent measurements of samples on a blood gas analyser. In 35 patie...

Harris T.R.; Nugent M., 1973: Development and evaluation of a new oxygen electrode for continuous monitoring of arterial oxygen tension in neo nates. Clinical Research 21(2): 319

Requena R.; Forte R.; Scherrer J.; Knopf M.; Kirschner J.; Levowitz B.S., 1972: Electrode catheter for continuous blood and tissue oxygen tension monitoring. Bulletin of the New York Academy of Medicine 48(8): 1052

Brown, E.G.; Liu, C.C.; McDonnell, F.E.; Neuman, M.R.; Sweet, A.Y., 1973: Unique electrode catheter for continuous monitoring of arterial blood oxygen tension in newborn infants. Advances in Experimental Medicine and Biology 37: 1103-1108

Ueda M.; Tanaka A.; Maekawa K.; Watanabe N.; Kazui T.; Komatsu S., 1984: Monitoring of left ventricular activity during treadmill exercise test before and after open heart surgery the evaluation of dynamic exercise by continuous measurement of cardiac output and monitoring of invasive blood pressure. Japanese Circulation Journal 48(8): 896

Pollitzer, M.J.; Soutter, L.P.; Reynolds, E.O., 1980: Continuous monitoring of arterial oxygen tension in infants: four years of experience with an intravascular oxygen electrode. Two hundred eighty-two umbilical artery catheters with oxygen electrodes on their tips were passed into the aortas of 268 newborn infants with severe respiratory illnesses between 1974-1977; 254 (90%) of the electrodes recorded PaO2 satisfactorily...

Pollitzer M.J.; Soutter L.P.; Reynolds E.O.R., 1980: Continuous monitoring of arterial oxygen tension in infants 4 years of experience with an intra vascular oxygen electrode. Umbilical artery catheters [282] with O2 electrodes on their tips were passed into the aortas of 268 newborn [human] infants with severe respiratory illnesses. Of the electrodes, 254 [90%] recorded PaO2 [arterial O2 pressure] satisfactorily for a...

Carlsen E.N., 1970: A new electrode system for continuous measurement of ph carbon di oxide tension oxygen tension and temperature on flowing blood. Jaami Journal Of The Association For The Advancement Of Medical Instrumentation: 136-144

Claremont, D.J.; Pagdin, T.M.; Walton, N., 1984: Continuous monitoring of blood PO2 in extracorporeal systems. An in vitro evaluation of a re-usable oxygen electrode. The technique of intermittent sampling of blood during extracorporeal circulation and in vitro analysis to establish that the blood-gas status of the patient is within acceptable limits has drawbacks which may be overcome by continuous monitoring....

Mcainsh A.M.; O'hare D.; Sheridan D.J.; Winlove C.P., 1992: Continuous measurement of oxygen tension in the isolated guinea pig heart using a purpose designed oxygen electrode. Journal of Physiology (Cambridge) 452: 126P