Evaluation of a non-invasive method for the measurement of metabolic rate in humans


Clinical Science 69(2): 135-141
Evaluation of a non-invasive method for the measurement of metabolic rate in humans
Measurements of O2 consumption (.ovrhdot.VO2) and CO2 production ($D+VCO2) can be used to calculate energy expenditure. Such data are useful in the nutritional management of a variety of pathological conditions. The mating of a canopy and a Beckmann metabolic measurement cart 1 (MMC) was evaluated in vivo and in vitro. The canopy allows for the collection of expired gases without facial attachments. Studies in vitro demonstrated the necessity of calibrating the CO2 analyzer at the concentrations used in such a system (0.50-0.80% CO2). Measurements of .ovrhdot.VO2 were within +12% to -8% of predicted values, and when calibrated at 0.50% and 0.75% CO2, measurements of .ovrhdot.VCO2 were within +2% and -7% of predicted values. The studies in vivo revealed that .ovrhdot.VO2 and .ovrhdot.VCO2 were within .+-. 11% of the values obtained by using a canopy-spirometer-computer system. The MMC plus canopy may provide an alternative method for the clinical measurement of .ovrhdot.VO2 and .ovrhdot.VCO2, especially in subjects unable to tolerate a tight-fitting mask for prolonged periods.


Accession: 005395465

PMID: 3933889

DOI: 10.1042/cs0690135



Related references

Tomographic measurement of local cerebral glucose metabolic rate in humans with (F-18)2-fluoro-2-deoxy-D-glucose: validation of method. Annals of Neurology 6(5): 371-388, 1979

Basal metabolic rate studies in humans: measurement and development of new equations. Public Health Nutrition 8(7a): 1133-1152, 2005

Non-Invasive Glucose Measurement by Use of Metabolic Heat Conformation Method. Sensors 8(5): 3335-3344, 2008

Apparatus and method for non-invasive measurement of current functional state and adaptive response in humans. Official Gazette of the United States Patent & Trademark Office Patents 1271(1), June 3, 2003

Effect of postprandial hyperglycaemia in non-invasive measurement of cerebral metabolic rate of glucose in non-diabetic subjects. European Journal of Nuclear Medicine and Molecular Imaging 29(2): 248-250, 2002

Measurement of gastric emptying rate in humans. Simplified scanning method. Digestive Diseases and Sciences 35(11): 1345-1351, 1990

N 13 ammonia dynamic positron emission tomography pet a new non invasive method for regional renal blood flow measurement in humans. Journal of the American Society of Nephrology 2(3): 516, 1991

Non invasive evaluation of autonomic nervous system activity by heart rate spectral analysis during tilt in humans. Experientia (Basel) 46(ABSTR): A68, 1990

Validation of a less-invasive method for measurement of serotonin synthesis rate with alpha-[11C]methyl-tryptophan. Journal of Cerebral Blood Flow and Metabolism 18(10): 1121-1129, 1998

Validation of a less-invasive method for measurement of serotonin synthesis rate with alpha-(11C)methyl-tryptophan. Journal of Cerebral Blood Flow and Metabolism 18(10): 1121-1129, 1998