Evaluation of blood gas quality control and proficiency testing materials by tonometry



Evaluation of blood gas quality control and proficiency testing materials by tonometry



American Review of Respiratory Disease 125(4): 480-483



Because of consistent differences found by other investigators and by us, we systematically tonometered, sampled, and measured PO2 and PCO2 concentrations of fresh blood, plasma, and several commercial quality control materials in three models of semiautomated blood gas machines. We found no significant differences between materials or machines for PCO2 between 25 to 72 mm Hg. For tonometered PO2 of approximately 25 to 100 mm Hg, the measured PO2 concentrations were accurate for blood, high for materials with hemoglobin or fluorocarbon (high O2 capacity), and very high for other materials (low O2 capacity). A low O2 capacity material tonometered to a PO2 of 0 mm Hg gave very high values in semiautomated machines and gave correct values only when injected repeatedly without interrupting rinse cycles into a manual machine. These findings indicate significant contamination of blood gas machines with fluids other than the sample so that low O2 capacity quality control materials are inadequate for proficiency testing at degrees of PO2 below 100 mm Hg.

(PDF emailed within 0-6 h: $19.90)

Accession: 005396726

Download citation: RISBibTeXText

PMID: 7073119

DOI: 10.1164/arrd.1982.125.4.480



Related references

Evaluation of different types of control materials in proficiency testing of creatinine measurement. Clinical Chemistry 42(6 PART 2): S276-S277, 1996

Proficiency testing for blood-gas quality control. Clinical Chemistry 22(10): 1675-1684, 1976

Dried tube specimens: a simple and cost-effective method for preparation of HIV proficiency testing panels and quality control materials for use in resource-limited settings. Journal of Virological Methods 163(2): 295-300, 2010

Application of a new AMIQAS computer program for integrated quality control, method evaluation and proficiency testing. Fresenius' Journal of Analytical Chemistry 345(2-4): 343-350, 1993

Heat treatment and the use of additives to improve the stability of paralytic shellfish poisoning toxins in shellfish tissue reference materials for internal quality control and proficiency testing. Toxicon 99: 80-88, 2016

External quality control in blood transfusion serology results from the finnish proficiency testing program in immuno hematology 1976 1978. Scandinavian Journal of Clinical & Laboratory Investigation 40(3): 249-252, 1980

Internal quality control, proficiency testing, and the clinical relevance of laboratory testing. Archives of Pathology & Laboratory Medicine 112(4): 449-453, 1988

Quality assurance in the mycobacteriology laboratory. Quality control, quality improvement, and proficiency testing. Clinics in Laboratory Medicine 16(3): 657-675, 1996

Ability of laboratories to detect emerging antimicrobial resistance: proficiency testing and quality control results from the World Health Organization's external quality assurance system for antimicrobial susceptibility testing. Journal of Clinical Microbiology 39(1): 241-250, 2001

Role of control materials in proficiency testing The case of glucose, sodium and potassium. Clinical Chemistry 40(6): 1002, 1994

Proficiency testing materials for pH and blood gases. The California Thoracic Society experience. Chest 89(2): 214-217, 1986

Specimen materials, target values and commutability for external quality assessment (proficiency testing) schemes. Clinica Chimica Acta 327(1-2): 25-37, 2003

Specimen materials, target values and commutability for external quality assessment (proficiency testing) schemes. Clinica Chimica Acta; International Journal of Clinical Chemistry 327(1-2): 25-37, 2002

External quality assessment/proficiency testing and internal quality control for the PFA-100 and PFA-200: an update. Seminars in Thrombosis and Hemostasis 40(2): 239-253, 2014