Evaluation of simultaneous measurement of left ventricular function by gated first pass radionuclide ventriculography with recorded mechanocardiogram



Evaluation of simultaneous measurement of left ventricular function by gated first pass radionuclide ventriculography with recorded mechanocardiogram



Journal of the Medical Society of Toho University 32(1): 133-141



Left ventricular volume curves were evaluated by using radio-isotope angiocardiography (RI angiocardiography) synchronized with electrocardiograms (ECG), phonocardiograms (PCG) and carotidograms to calculate systolic time intervals (STI) in 104 cases with various heart diseases and in 13 normal subjects. Left ventricular ejection time (LVET) was measured from the up-stroke (US) to the dicrotic notch (DN) on the carotidogram.

(PDF 0-2 workdays service: $29.90)

Accession: 005401542

Download citation: RISBibTeXText



Related references

Right ventricular ejection fraction measurement contrast ventriculography vs. gated blood pool and gated first pass radionuclide methods. American Journal of Cardiology 54(6): 651-653, 1984

Right ventricular ejection fraction measurement: contrast ventriculography versus gated blood pool and gated first-pass radionuclide methods. American Journal of Cardiology 54(6): 651-653, 1984

Effect of hemodialysis on left and right ventricular function--evaluation using electrocardiogram gated radionuclide ventriculography. Radioisotopes 35(3): 122-126, 1986

Measurement of left ventricular function at rest and exercise by gated radionuclide ventriculography in 50 patients with orthotopic cardiac graft. European Journal of Nuclear Medicine 14(5-6): 267, 1988

Operator-interactive method for simultaneous measurement of left and right ventricular volumes and ejection fraction by tomographic electrocardiography-gated blood pool radionuclide ventriculography. Journal of Nuclear Cardiology 13(1): 50-63, 2006

Left ventricular function in patients with coronary artery disease assessed by gated tomographic myocardial perfusion images. Comparison with assessment by contrast ventriculography and first-pass radionuclide angiography. Journal of the American College of Cardiology 27(1): 173-181, 1996

Effects of spontaneous respiration on right and left ventricular function: evaluation by respiratory and ECG gated radionuclide ventriculography. Journal of Nuclear Medicine 28(2): 173-177, 1987

Assessment of left ventricular ejection fraction measured by quantitative gated SPECT: correlation with left ventriculography and first-pass radionuclide angiography. International Journal of Cardiovascular Imaging 22(2): 223-230, 2005

Non-invasive measurement of left ventricular function in coronary artery disease. Comparison of first pass radionuclide ventriculography, M-mode echocardiography, and systolic time intervals. British Heart Journal 45(4): 369-375, 1981

Regional ejection fractions to determine left ventricular function. Comparison of first-radionuclide-pass and equilibrium-radionuclide-ventriculography with the results of cineventriculography. Rofo 137(4): 456-461, 1982

Comparison of two-dimensional echocardiography with gated radionuclide ventriculography in the evaluation of global and regional left ventricular function in acute myocardial infarction. Journal of the American College of Cardiology 3(2 Pt 1): 243-252, 1984

Feasibility and accuracy of gated blood pool SPECT equilibrium radionuclide ventriculography for the assessment of left and right ventricular volumes and function in patients with left ventricular assist devices. Journal of Nuclear Cardiology, 2016

Left ventricular performance during exercise in patients with left bundle branch block: evaluation by gated radionuclide ventriculography. American Heart Journal 105(1): 66-71, 1983

Automatic measurement of left ventricular ejection fraction by gated SPECT Tc-99m sestamibi A comparison with radionuclide ventriculography. Circulation 88(4 PART 2): I582, 1993

Noninvasive assessment of left ventricular function by gated radionuclide ventriculography in patients on hemodialysis. Nephrology Dialysis Transplantation 15(9): A138, September, 2000