Extended use of disposable pressure transducers






Journal of the American Medical Association 255(7): 916-920

Extended use of disposable pressure transducers

In a prospective randomized study, contamination rates of disposable pressure transducers changed every two days (n = 81) were compared with those changed at four (n = 26) or eight days (n = 50); the mean daily incidence of contamination was 3% for each group. After four days of use, the cumulative prevalences of contamination were similar. However, after eight days, the cumulative prevalence was significantly higher in transducers used without change (6.9%) than in those changed every two days (2.9%). Gram-negative bacilli were present in 63% of contaminated transducers; over half were from the patients' own flora. The only definite transducer-related bacteremia ocurred on a day of initial contamination and should have been unaffected by the interval of change. Routine use of disposable transducers can be safely extended to four days, even in a busy intensive care unit.


Accession: 005432694

DOI: 10.1001/jama.1986.03370070070028



Related references

Luskin, R.L.; Weinstein, R.A.; Nathan, C.; Chamberlin, W.H.; Kabins, S.A., 1986: Extended use of disposable pressure transducers. A bacteriologic evaluation. In a prospective randomized study, contamination rates of disposable pressure transducers changed every two days (n = 81) were compared with those changed at four (n = 26) or eight days (n = 50); the mean daily incidence of contamination was 3% fo...

Matzek F.; Boenick U.; Frucht U.; Schroeder P M., 1989: Comparison of the performance of disposable pressure transducers for invasive blood pressure measurement. This paper reports on the results of a study in which the offset drift, sensitivity and error and drift, as well as the linearity errors of six DPT's were investigated under normal ambient conditions and varying conditions of temperature, lig...

Gardner, R.M., 1996: Accuracy and reliability of disposable pressure transducers coupled with modern pressure monitors. Objective: To determine the bedside accuracy of direct patient Pressure monitoring when used with new and clinically used disposable blood pressure (BP) transducers. Design: Prospective study. Setting: Laboratory bench and critical care units in a...

Anonymous, 1988: Mismatch between Hewlett-Packard 78205D pressure modules and disposable pressure transducers. Health Devices 17(9): 277-277

Anonymous, 1988: Disposable pressure transducers and multiple-pressure-channel physiologic monitors. Health Devices 17(11): 357-357

Anonymous, 1988: Disposable pressure transducers. We evaluated twelve disposable pressure transducers from eleven manufacturers. All were rated Acceptable and were ranked in four groups. The first two groups had similar performance characteristics. Groups three and four were ranked primarily acco...

Gordon, V.L.; Welch, J.P.; Carley, D.; Teplick, R.; Newbower, R.S., 1987: Zero stability of disposable and reusable pressure transducers. Zero stability tests were performed on contrasting, commercially available, blood pressure-transducer systems. One system was based on a brand of disposable transducer. The others employed one brand of reusable transducer with and without samples...

Meyer R.M., 1988: Accuracy of disposable versus reusable pressure transducers. Anesthesiology (hagerstown): A305

Anonymous, 1993: Disposable blood pressure transducers: calibration methods. Health Devices 22(2): 97-97

Piek, J.; Krämer, M.; Bock, W.J., 1987: Continuous registration of intracranial pressure using disposable transducers. The authors report the results of physical tests (baseline drift, temperature drift, absolute accuracy) and clinical experiences in intraventricular intracranial pressure monitoring with disposable transducers. Physical tests gave excellent result...