Extended use of disposable pressure transducers


Journal of the American Medical Association 255(7): 916-920
Extended use of disposable pressure transducers
In a prospective randomized study, contamination rates of disposable pressure transducers changed every two days (n = 81) were compared with those changed at four (n = 26) or eight days (n = 50); the mean daily incidence of contamination was 3% for each group. After four days of use, the cumulative prevalences of contamination were similar. However, after eight days, the cumulative prevalence was significantly higher in transducers used without change (6.9%) than in those changed every two days (2.9%). Gram-negative bacilli were present in 63% of contaminated transducers; over half were from the patients' own flora. The only definite transducer-related bacteremia ocurred on a day of initial contamination and should have been unaffected by the interval of change. Routine use of disposable transducers can be safely extended to four days, even in a busy intensive care unit.

(PDF same-day service: $19.90)

Accession: 005432694

DOI: 10.1001/jama.1986.03370070070028



Related references

Extended use of disposable pressure transducers. A bacteriologic evaluation. JAMA 255(7): 916-920, 1986

Comparison of the performance of disposable pressure transducers for invasive blood pressure measurement. Biomedizinische Technik 34(3): 34-41, 1989

Accuracy and reliability of disposable pressure transducers coupled with modern pressure monitors. Critical Care Medicine 24(5): 879-882, 1996

Mismatch between Hewlett-Packard 78205D pressure modules and disposable pressure transducers. Health Devices 17(9): 277-277, 1988

Disposable pressure transducers and multiple-pressure-channel physiologic monitors. Health Devices 17(11): 357-357, 1988

Disposable pressure transducers. Health Devices 17(12): 367-368, 1988

Zero stability of disposable and reusable pressure transducers. Medical Instrumentation 21(2): 87-91, 1987

Accuracy of disposable versus reusable pressure transducers. Anesthesiology (hagerstown): A305, 1988

Disposable blood pressure transducers: calibration methods. Health Devices 22(2): 97-97, 1993

Continuous registration of intracranial pressure using disposable transducers. Anasthesie, Intensivtherapie, Notfallmedizin 22(1): 30-32, 1987