Isolation of legionella pneumophila from cooling tower water by filtration



Isolation of legionella pneumophila from cooling tower water by filtration



Applied & Environmental Microbiology 41(5): 1202-1205



Methods are described for detection of L. pneumophila in cooling tower water or other water sources by direct fluorescent-antibody staining. A procedure for isolation of Legionella bacteria from water samples by guinea pig inoculation is described. Two different serogroups of L. pneumophila were isolated repeatedly from 1 of the cooling towers.

Please choose payment method:






(PDF emailed within 1 workday: $29.90)

Accession: 005770839

Download citation: RISBibTeXText

PMID: 7020594


Related references

Isolation of Legionella pneumophila from chlorinated water and water from industrial cooling tower. Bangladesh Journal of Microbiology 11(2): 111-114, 1994

Negative enrichment procedure for isolation of Legionella pneumophila from seeded cooling tower water. Applied and Environmental Microbiology 40(4): 849-851, 1980

Improved facility and sensitivity in the use of guinea pigs for the isolation of Legionella pneumophila from cooling tower water. Applied and Environmental Microbiology 45(3): 1119-1121, 1983

Isolation of Legionella pneumophila from cooling tower. Kansenshogaku Zasshi. Journal of the Japanese Association for Infectious Diseases 55(6): 439-446, 1981

Ecological studies of Legionella species. I. Viable counts of Legionella pneumophila in cooling tower water. Microbiology and Immunology 30(5): 413-423, 1986

Isolation of Legionella pneumophila from the UOEH cooling tower. Journal of Uoeh 8(4): 423-428, 1986

Isolation of Legionella pneumophila from cooling tower in China. Kansenshogaku Zasshi. Journal of the Japanese Association for Infectious Diseases 59(8): 787-792, 1985

Enumeration of Legionella pneumophila in cooling tower water systems. Environmental Monitoring and Assessment 100(1-3): 53-58, 2005

Efficacy of methylchloromethylisothiazolone biocide against legionella pneumophila in cooling tower water. Journal of Industrial Microbiology 1(1): 49-56, 1986

Detection of Legionella pneumophila by PCR-ELISA method in industrial cooling tower water. Pakistan Journal of Biological Sciences 10(22): 4015-4021, 2009

Distinct difference of flaA genotypes of Legionella pneumophila between isolates from bath water and cooling tower water. Microbiology and Immunology 52(9): 460-464, 2008

Factors affecting the recovery of Legionella pneumophila serogroup 1 from cooling tower water systems. Journal of Microbiology, Immunology, and Infection 34(3): 161-166, 2001

Identification of Legionella pneumophila strains by polymerase chain reaction method which isolated from cooling tower water. Kansenshogaku Zasshi. Journal of the Japanese Association for Infectious Diseases 69(1): 79-84, 1995

Evaluation of the dynal biotech Legionella immunomagnetic separation method vs. conventional culture for the isolation of Legionella from cooling tower water samples. 2006

Development of an improved PCR-ICT hybrid assay for direct detection of Legionellae and Legionella pneumophila from cooling tower water specimens. Water Research 40(11): 2221-2229, 2006