+ Recently Requested

Laboratory comparison of modern vacuum extractors



Laboratory comparison of modern vacuum extractors



Obstetrics and Gynecology 71(2): 155-158



The Malmström, Soft Cup, and Mity-Vac vacuum extractors were compared in the laboratory using a tensile strength tester and a fetal cephalic model. In the test system, a linear relationship emerged between applied vacuum and maximal tractive force for all of the vacuum extractors. At their recommended working pressures, they allowed a maximum of 18-20 kg of tractive force to assist in a delivery. Calculation of the distribution of this force per unit area would appear to favor the Soft Cup. At high vacuums, all showed large amounts of tractive force and high forces per unit area. The data clearly demonstrate that high vacuum would have potentially adverse effects on the fetus and thus should be avoided.

Please choose payment method:






(PDF emailed within 1 workday: $29.90)

Accession: 005787566

Download citation: RISBibTeXText

PMID: 3336548


Related references

Effect of angular traction on the performance of modern vacuum extractors. American Journal of Obstetrics and Gynecology 167(4 Pt 1): 1125-1129, 1992

Personal experiences in the use of vacuum extractors in obstetrics. 3. Remote results of follow-up studies of children delivered by vacuum extraction. Ginekologia Polska 43(1): 37-41, 1971

Notes on the obstetrical vacuum extractor in the articles of Th. Sohie: "Extraction with vacuum extractor in tropical practice" and P. Sterckx: "Obstetrical vacuum extractors". Annales de la Societe Belge de Medecine Tropicale 37(5): 573-576, 1957

Vacuum extractors. Nordisk Medicin 65: 541-544, 1961

Our experience with vacuum extractors. Ceskoslovenska Gynekologie 31(6): 413-415, 1966

Obstetrical vacuum extractors. Annales de la Societe Belge de Medecine Tropicale 37(5): 689-692, 1957

Report on 132 deliveries by vacuum extractors. Geburtshilfe und Frauenheilkunde 19(3): 274-278, 1959

Experience with vacuum extractors in Czechoslovakia and abroad. Ceskoslovenska Gynekologie 31(6): 401-407, 1966

Application of vacuum extractors in clinical obstetrics. Ginekologia Polska 36(8): 873-876, 1965

Clinical evaluation of children delivered with the aid of vacuum extractors. Pediatria Polska 37: 611-616, 1962

The effect of artificial caput on performance of vacuum extractors. Obstetrics and Gynecology 81(2): 170-173, 1993

Apropos of "obstetrical vacuum extractors". The reasonable apparatus. Revue Francaise de Gynecologie et D'obstetrique 57: 569-571, 1962

Experience with the use of skin-head forceps with vacuum extractors in 10 deliveries. Pediatriia Akusherstvo i Ginekologiia 2: 42-44, 1962

Clinical And Statistical Observations On 195 Children Between 2 And 3 Years Of Age Delivered By Vacuum Extractors. Revista Clinica. Lisbon. Instituto Maternal 14: 27-29, 1963

Vacuum trough extractors for measuring drainage and nitrate flux through sandy soils. Soil Science Society of America Journal 51(2): 271-276, 1987