Reproducibility of photogrammetric optic disc cup measurements



Reproducibility of photogrammetric optic disc cup measurements



Investigative Ophthalmology and Visual Science 26(6): 814-817



To detect early glaucoma-associated changes in the optic disc cup, the authors analyzed reproducibility of optic disc cup measurements by photogrammetry of three age-matched groups: 10 normal, 10 ocular hypertensive, and 10 glaucomatous subjects. For each eye, three simultaneous stereophotographs were taken on the same day and one measurement was made for each stereophotograph. In order to reduce the effects of refractive error of the eye and photographic magnification, the authors computed cup parameters as relative measurements, ie, a ratio to the optic disc area. The median coefficients of variation for glaucomatous eyes were 4.5% for cup volume/disc area, 6.1% for cup depth/disc area, and 4.7% for cup area/disc area. Coefficients of variation of normal and ocular hypertensive subjects were slightly larger than those of glaucomatous subjects. Coefficients of variation generally were larger for quadrants than for total disc area. These findings suggest that the photogrammetric technique is highly reproducible and sensitive and could be a valuable quantitative technique for the clinical study of glaucoma.

(PDF emailed within 1 workday: $29.90)

Accession: 006315226

Download citation: RISBibTeXText

PMID: 4008193


Related references

Comparison between stereo- and slit image photogrammetric measurements of the optic disc. Acta Ophthalmologica 50(6): 863-871, 1972

Reproducibility of RTVue retinal nerve fiber layer thickness and optic disc measurements and agreement with Stratus optical coherence tomography measurements. American Journal of Ophthalmology 147(6): 1067-74, 1074.E1, 2009

Reproducibility of optic disc measurements with computerized analysis of stereoscopic video images. Archives of Ophthalmology 104(7): 1035-1039, 1986

The reproducibility of computerized boundary analysis for measuring optic disc pallor in the normal optic disc. Ophthalmology 92(2): 243-251, 1985

Reproducibility of evaluation of optic disc change for glaucoma with stereo optic disc photographs. Ophthalmology 110(2): 340-344, February, 2003

The Ocular Hypertension Treatment Study: Reproducibility of cup/disk ratio measurements over time at an Optic Disc Reading Center. American Journal of Ophthalmology 133(1): 19-28, January, 2002

Variability of optic disc topography measurements on the rodenstock optic disc analyzer roda. Investigative Ophthalmology & Visual Science 28(3 SUPPL): 188, 1987

An optic disc grid: its evaluation in reproducibility studies on the cup/disc ratio. British Journal of Ophthalmology 67(6): 356-361, 1983

Reproducibility of readings of optic disc cup/disc ratios in the ocular hypertension treatment study. IOVS 40(4): S283, March 15, 1999

Reproducibility of photogrammetric nerve fiber layer thickness measurements. Investigative Ophthalmology & Visual Science 28(3 SUPPL): 187, 1987

A new digital optic disc stereo-camera Intra-observer and inter-observer repeatability of optic disc measurements. IOVS 40(4): S74, March 15, 1999

Membrane tissue on the optic disc may cause macular schisis associated with a glaucomatous optic disc without optic disc pits. Clinical Ophthalmology 7: 883-887, 2013

Variability and reproducibility of optic disk topographic measurements with the Rodenstock Optic Nerve Head Analyzer. American Journal of Ophthalmology 106(6): 696-702, 1988

Ratio of disc measurements in diagnosis of hypoplasia of the optic disc. Survey of Ophthalmology 30(3): 212, 1985