Reproducibility of transcutaneous oxygen pressure measurements in normal volunteers



Reproducibility of transcutaneous oxygen pressure measurements in normal volunteers



Clinical Physics & Physiological Measurement 7(3): 259-264



The transcutaneous oxygen monitor was developed as a non-invasive method of measuring arterial oxygen tension in neonates and has since been applied to adults as a method of assessing circulatory impairment due to peripheral vascular disease. Transcutaneous oxygen pressure measurements (tcPO2) were taken daily on normal volunteers for a period of three weeks to determine the reproducibility of tcPO2 measurements. Results varied by an average of almost 10% from the mean for each individual. This variation was not clinically significant since the variation did not result in readings below 35-40 mmHg, this being the level which reflects severe skin ischaemia. The correlation between simultaneous chest and leg readings was not sufficient to recommend this ratio as an accurate index of vascular insufficiency.

Please choose payment method:






(PDF emailed within 1 workday: $29.90)

Accession: 006315309

Download citation: RISBibTeXText


Related references

Reproducibility of transcutaneous oxygen pressure measurements in persons with spinal cord injury. Archives of Physical Medicine and Rehabilitation 90(3): 507-511, 2009

Reproducibility of proximal and distal transcutaneous oxygen pressure measurements during exercise in stage 2 arterial claudication. International Angiology 23(2): 114-121, 2004

The influence of epidermal thickness on transcutaneous oxygen pressure measurements in normal persons. Scandinavian Journal of Clinical and Laboratory Investigation 48(6): 519-523, 1988

The reproducibility of transcutaneous oxygen pressure by continuous registration. Vasa. Supplementum 35: 32-33, 1992

Variability and reproducibility of transcutaneous oxygen tension measurements in the assessment of peripheral vascular disease. Angiology 40(8): 695-700, 1989

Short-term reproducibility of intraocular pressure and ocular perfusion pressure measurements in Chinese volunteers and glaucoma patients. Bmc Ophthalmology 16: 145, 2016

Reproducibility of tcPO2 measurements in normal volunteers. Clinical Physics and Physiological Measurement 7(3): 259-263, 1986

Evaluation of the microcirculatory effects of venoruton in patients with chronic venous hypertension by laser doppler flowmetry transcutaneous oxygen partial pressure and carbon dioxide partial pressure measurements leg volumetry and ambulatory venous pressure measurements. Vasa 18(2): 146-151, 1989

The effect of age and sex of normal volunteers upon the transcutaneous oxygen tension in the lower limb. Clinical Physics and Physiological Measurement 4(1): 65-68, 1983

Reproducibility of cardiac measurements by cine mr in normal volunteers between sequential studies. Investigative Radiology 24(12): S105, 1989

Transcutaneous oxygen partial pressure and systolic malleolar artery pressure in patients with peripheral arterial occlusive disease. Longitudinal measurements over 14 days. Medizinische Klinik 88(10): 564-567, 1993

Transcutaneous partial oxygen pressure measurements with new types of electrodes. Mahler, F , K Messmer And F Hammersen (Ed ) Methoden Der Klinischen Kapillarmikroskopie (Methods Of Clinical Capillary Microscopy); Fifth Lake Constance Symposium on Microcirculation, Konstanz on Lake Constance, West Germany, May 31-June 2, 1985 Xi+167p S Karger Ag: Basel, Switzerland; New York, N Y , Usa Illus Paper 124-136, 1986

Transcutaneous oxygen pressure measurements in patients with intermittent claudication. Clinical Physiology 14(4): 385-391, 1994

Transcutaneous oxygen pressure measured at two different electrode core temperatures in healthy volunteers and patients with arterial occlusive disease. International Journal of Microcirculation Clinical and Experimental 5(4): 373-380, 1987

Radiation dosimetry estimates for oxygen 15 butanol and oxygen 15 water based on pet measurements in normal volunteers. Journal of Nuclear Medicine 32(5 Suppl.): 1043, 1991