EurekaMag.com logo
+ Site Statistics
References:
52,725,316
Abstracts:
28,411,598
+ Search Articles
+ Subscribe to Site Feeds
EurekaMag Most Shared ContentMost Shared
EurekaMag PDF Full Text ContentPDF Full Text
+ PDF Full Text
Request PDF Full TextRequest PDF Full Text
+ Follow Us
Follow on FacebookFollow on Facebook
Follow on TwitterFollow on Twitter
Follow on Google+Follow on Google+
Follow on LinkedInFollow on LinkedIn

+ Translate

Scanning electron microscopy methodology for study of the pathophysiology of calcification in bioprosthetic heart valves


Scanning Electron Microscopy: 209-213
Scanning electron microscopy methodology for study of the pathophysiology of calcification in bioprosthetic heart valves
Scanning electron microscope (SEM) morphologic analysis combined with energy dispersive characteristic X-ray (EDX) microprobe analysis provides insight into the mechanisms associated with disease-related crystal formation in biological materials. SEM and EDX were employed in analyzing specimens which were embedded in standard fashion in glycolmethacrylate. The specimen surfaces under electron microscope investigation resulted from microtomy used in the preparation of reference light microscope histological sections; thus histology served as a direct reference for the SEM and EDX analyses. The particular application of these methods was in the study of bioprosthetic heart valve calcification, largely responsible for clinical failure of these heart valve substitutes. To simulate the clinically observed mineralization processes, glutaraldehyde-pretreated porcine heart valve leaflets were implanted subcutaneously in rats and subsequently removed at various time intervals from 1 to 56 days. Also, to address the hypothesis that the calcification process generates crystalline materials analogous to those in bone, EDX data obtained from pure hydroxyapatite were compared with the embedded tissue results. Further, EDX results were compared with data obtained by chemical analysis of the bulk specimens to assess the validity of the electron microscope technique.


Accession: 006365347

PMID: 4001850



Related references

Scanning electron microscopy studies of the prevention of bioprosthetic heart valve calcification with controlled release polymeric matrices. Cells & Materials 1(1): 65-72, 1991

Changes in the endothelial morphology of the developing semilunar heart valves a transmission electron microscopy and scanning electron microscopy study in the chick. Anatomy & Embryology 167(1): 67-84, 1983

Confocal laser scanning microscopy of calcified bioprosthetic heart valves. Journal of Heart Valve Disease 3(2): 205-211, 1994

Calcification of aortic vs. mitral porcine bioprosthetic heart valves a radiographic study comparing amounts of calcific deposits in valves explanted from the same patient. American Journal of Cardiology 54(8): 1030-1032, 1984

Calcification of aortic versus mitral porcine bioprosthetic heart valves: a radiographic study comparing amounts of calcific deposits in valves explanted from the same patient. American Journal of Cardiology 54(8): 1030-1032, 1984

Scanning electron microscopy 1977 vol 1 proceedings of the 10th annual scanning electron microscope symposium and workshops on materials and component characterization quality control with the scanning electron microscopy scanning transmission electron microscopy scanning electron microscopy application to semi conductors analytical electron microscopy biological specimen preparation for scanning electron microscopy chicago illinois usa march 28 april 1 1977. Scanning Electron Microscopy 784, 1977

Is degenerative calcification of the native aortic valve similar to calcification of bioprosthetic heart valves?. Journal of Thoracic and Cardiovascular Surgery 126(4): 939-941, 2003

Calcification of bioprosthetic heart valves and its assessment. Journal of Thoracic and Cardiovascular Surgery 121(3): 428-430, 2001

SnapShot: calcification of bioprosthetic heart valves. Biomaterials 30(26): 4445-4446, 2009

Heart valves in rheumatic heart disease in the light of scanning electron microscopy. Kardiologiia 15(11): 57-61, 1975