Spectral sensitivity function measured by a rapid scan flicker photometric procedure


, : Spectral sensitivity function measured by a rapid scan flicker photometric procedure. Investigative Ophthalmology & Visual Science 18(12): 1264-1272

A rapid scan flicker photometric procedure is described whereby continuous spectral sensitivity functions are measured from unpracticed observers in 30 min. The 30 min includes instructions, practice, and data collection. Data are presented from four unpracticed observers age 12 to 42 years. Three practiced observers had their spectral sensitivities measured by both the conventional and rapid scan methods. The conventional method took 1.5 hr, measuring at 25 wavelengths and repeating each three times. The agreement between the rapid scan and conventional methods is satisfactory. Comparison with Judd's correction of CIEV (lambda) yields the same deviations as expected with conventional flicker photometry. The rapid scan procedure is shown to yield acceptably consistent data. The advantages of the rapid scan method for basic and applied vision research is discussed.

(PDF 0-2 workdays service)

Accession: 006459856

PMID: 511467

Submit PDF Full Text: Here


Submit PDF Full Text

No spam - Every submission is manually reviewed

Due to poor quality, we do not accept files from Researchgate

Submitted PDF Full Texts will always be free for everyone
(We only charge for PDFs that we need to acquire)

Select a PDF file:
Close
Close

Related references

Kaiser P.K., 1979: Spectral sensitivity by rapid scan flicker photometry. Investigative Ophthalmology & Visual Science (SUPPL): 172

Bornstein M.H.; Marks L.E., 1972: Spectral sensitivity measured by a procedure of flicker threshold. American Journal of Optometry & Archives of American Academy of Optometry 49(10): 893

Bornstein, M.H.; Marks, L.E., 1973: Studies of spectral sensitivity as measured by a procedure of flicker threshold. American Journal of Optometry and Archives of American Academy of Optometry 50(5): 376-382

Laxar, K.; Kass, D.; Wooten, B.R., 1984: Flicker-photometric spectral sensitivity in the presence of chromatic surrounds. Flicker-photometric spectral sensitivity is measured in the presence and absence of superimposed monochromatic surrounds. Although color appearance depends on surround wavelength, the shape of the flicker-spectral-sensitivity functions are unaffec...

Eisner, A., 1982: Comparison of flicker-photometric and flicker-threshold spectral sensitivities while the eye is adapted to colored backgrounds. Journal of the Optical Society of America 72(4): 517-518

Jacobs, G.H.; Deegan, J.F., 1997: Spectral sensitivity of macaque monkeys measured with ERG flicker photometry. Macaque monkeys are widely used as a model species for investigations of the biology of human vision. Previous measurements suggest that the cone-based spectral sensitivity of these two primates is greatly similar, but perhaps not identical. We me...

Jacobs, GH.; Neitz, J.; Crognale, M., 1985: Spectral sensitivity of ground squirrel cones measured with ERG flicker photometry. Ground squirrels have dichromatic color vision. The spectral sensitivities of the 2 classes of cones found in the retinas of 2 spp. of ground squirrel were measured using ERG electroretinography flicker photometry. The spectral sensitivity curves...

Jacobs G.H.; Neitz J., 1986: Spectral sensitivity of cat cones to rapid flicker. Records obtained from the flicker photometric electroretinogram indicate that only a single spectral mechanism (.lambda.MAX = 555 nm) in the cat eye contributes to the response to 50 Hz flicker. A photopic mechanism (.lambda.MAX = 500-510 nm) dete...

Jacobs G.H.; Neitz J.; Crognale M., 1985: Spectral sensitivity of ground squirrel cones measured with electroretinographic flicker photometry. Ground squirrels have dichromatic color vision. The spectral sensitivities of the 2 classes of cones found in the retinas of 2 spp. of ground squirrel were measured using ERG [electroretinography] flicker photometry. The spectral sensitivity curve...

Rovamo, J.; Raninen, A.; Lukkarinen, S.; Donner, K., 1996: Flicker sensitivity as a function of spectral density of external white temporal noise. Foveal flicker sensitivity at 0.5-30 Hz was measured as a function of the spectral density of external, white, purely temporal noise for a sharp-edged 2.5 deg circular spot (mean luminance 3.4 log phot td). Sensitivity at any given temporal freque...