Spectral signature of the opening sound of the bjork shiley convexoconcave valve as a potential indicator of strut fracture


, : Spectral signature of the opening sound of the bjork shiley convexoconcave valve as a potential indicator of strut fracture. American Journal of Noninvasive Cardiology 1(6): 369-372

The Bjork-Shiley cardiac-valve prosthesis with a 60.degree. opening convexoconcave disc (BSCC) has failed by fracture at the base of the outlet (short) strut in 206 patients as of March, 1987. There are approximately 25,000 29- to 33-mm and 57,600 21- to 27-mm valves implanted worldwide although 57% of fractures were among 9,4000 29- to 33-mm valves manufactured between February 1981 and June 1982. Once mechanical failure of a valve occurs, reoperation is required within hours. It would be useful, therefore, to identify fracture of a strut before complete failure of the valve occurs. For this purpose, we evaluated in vitro the potential of spectral analysis of the prosthetic valve sound as a noninvasive indicator of strut fracture. An intact 29-mm BSCC valve and a normally functioning 29-mm BSCC valve with a through-and-through fracture of the outlet structure at one welding point were examined in the mitral position of a pulse duplicator (pressure 120/80 mm Hg, rate 70/min). Clear differences of the opening sound were observed. The dominant frequency of the opening sound of the intact valve was 234 Hz and the valve with a fractured strut was 78 Hz. A correlation between the frequency spectrum of the opening sound of the two valves was poor (correlation coefficient of 0.22), indicating a marked difference of the spectral signature. These in vitro observations suggest that frequency analysis of the opening sound of BSCC valves has the potential for a noninvasive identification of subclinical strut fracture.

(PDF 0-2 workdays service)

Accession: 006459920

Submit PDF Full Text: Here


Submit PDF Full Text

No spam - Every submission is manually reviewed

Due to poor quality, we do not accept files from Researchgate

Submitted PDF Full Texts will always be free for everyone
(We only charge for PDFs that we need to acquire)

Select a PDF file:
Close
Close

Related references

Lemke B.; Rathmann J.; Wiebe V.; Witzel U., 1991: Strut fracture of the bjork shiley 60 degrees convexoconcave valve 5 years after implantation metallurgic analysis of the outlet strut. Zeitschrift fuer Kardiologie 80(8): 537-540

Gonzalez Lavin L.; Mcgrath L.B.; Fernandez J.; Quinlan W.C., 1986: Strut fracture and other events following valve replacement with the 60 degree convexoconcave bjork shiley prosthesis. American Heart Association Monograph (124): II-337

Mok C K.; Lee J.W T.; Kong S M.; Hui K.K K., 1985: Experience with outlet strut fracture of the bjork shiley convexoconcave mitral valve prosthesis. Within a period of 15 months, we encountered five patients with outlet strut fracture of the Bjork-Shiley convexoconcave mitral valve prosthesis. All of the patients had acute failure of the left side of the heart and pulmonary edema. The diagnosi...

Gonzalez Lavin L.; Mcgrath L.B.; Grunkemeier G.; Fernandez J.; Lewis B.; Quinlan W., 1987: Strut fracture and other events after valve replacement with the 60 degree convexoconcave bjork shiley prosthesis. Circulation 76(3 PART 2): III-137-III-140

Mok, C.K.; Lee, J.W.; Kong, S.M.; Hui, K.K., 1985: Experience with outlet strut fracture of the Björk-Shiley convexoconcave mitral valve prosthesis. Within a period of 15 months, we encountered five patients with outlet strut fracture of the Björk-Shiley convexoconcave mitral valve prosthesis. All of the patients had acute failure of the left side of the heart and pulmonary edema. The diagnos...

Gonzalez-Lavin, L.; McGrath, L.B.; Grunkemeier, G.; Fernandez, J.; Lewis, B.; Quinlan, W., 1987: Strut fracture and other events after valve replacement with the 60 degree convexoconcave Björk-Shiley prosthesis. A total of 688 patients received 808 Björk-Shiley prostheses during a 5 year span. Cumulative duration of follow-up totaled 1175.4 patient-years (1368 valve-years). Linearized rates in percent per patient-year for valve-related events (95% confid...

Goovaerts, J.; D.G.est, H., 1986: Outlet strut fracture of the 27 mm convexoconcave Björk-Shiley mitral valve prosthesis. Report of 2 cases. Two patients with outlet strut fracture of the convexoconcave Björk-Shiley mitral valve prosthesis are described and all published cases are reviewed. The pertinent clinical, diagnostic and therapeutic features are discussed. Prompt recognition o...

Goovaerts J.; D.G.est H., 1986: Outlet strut fracture of the 27 millimeter convexoconcave bjork shiley mitral valve prosthesis report of 2 cases. Acta Cardiologica 41(4): 305-312

Khalil, Y.; Sethia, B.; Quin, R.O.; Bain, W.H., 1985: Disc and strut embolisation after minor strut fracture in a Björk-Shiley mitral valve prosthesis. Thorax 40(2): 158-159

Khalil Y.; Sethia B.; Quin R.O.; Bain W.H., 1985: Disc and strut embolization after minor strut fracture in a bjork shiley mitral valve prosthesis. Thorax 40(2): 158-159