The diagnosis of loosening in total hip prosthesis clinical radiographic and scintigraphic investigation


, : The diagnosis of loosening in total hip prosthesis clinical radiographic and scintigraphic investigation. Italian Journal of Orthopaedics & Traumatology 13(2): 167-172

Based on the authors' clinical experience and a review of the literature, the methods used for the diagnosis of loosening in hip arthroprostheses are considered. Clinical and radiographic monitoring are essential but the authors believe that in suspected loosening it is particularly important to perform bone scintigraphy using Tc 99 M.D.P., Ga 67, and Indium 111. Arthrography is advised only in selected cases. The criteria of evaluation in the various tests are reported and a procedure for diagnosis is proposed.


Accession: 006628404

PMID: 3482832

Submit PDF Full Text: Here


Submit PDF Full Text

No spam - Every submission is manually reviewed

Due to poor quality, we do not accept files from Researchgate

Submitted PDF Full Texts will always be free for everyone
(We only charge for PDFs that we need to acquire)

Select a PDF file:
Close
Close

Related references

Lorenzi, G.L.; Rossi, P.; Denicolai, F.; Dettoni, A.; Quaglia, F., 1987: The diagnosis of loosening in total hip prostheses. Clinical, radiographic and scintigraphic investigation. Based on the authors' clinical experience and a review of the literature, the methods used for the diagnosis of loosening in hip arthroprostheses are considered. Clinical and radiographic monitoring are essential but the authors believe that...

Oyen, W.J.; Lemmens, J.A.; Claessens, R.A.; van Horn, J.R.; Slooff, T.J.; Corstens, F.H., 1996: Nuclear arthrography: combined scintigraphic and radiographic procedure for diagnosis of total hip prosthesis loosening. Radiographic arthrography and bone scintigraphy are common diagnostic procedures used for evaluating total hip prostheses. In this study, both techniques are combined, and nuclear contrast imaging (nuclear arthrography) is added. The efficacy of t...

Uri G.; Wellman H.; Robb J.; Greenman G.; Capello W., 1984: Scintigraphic and x ray arthrographic diagnosis of femoral prosthesis loosening. In order to determine loosening of femoral components of conventional total hip arthroplasties, a comparison of radionuclide (RA) and radiographic arthrograms (XA) was performed. The hips of 29 patients were studied with radiographic contrast and...

Uri, G.; Wellman, H.; Capello, W.; Robb, J.; Greenman, G., 1984: Scintigraphic and X-ray arthrographic diagnosis of femoral prosthesis loosening: concise communication. In order to determine loosening of femoral components of conventional total hip arthroplasties, a comparison of radionuclide (RA) and radiographic arthrograms (XA) was performed. The hips of 29 patients were studied with radiographic contrast and...

Temmerman, O.P.P.; Raijmakers, P.G.H.M.; David, E.F.L.; Pijpers, R.; Molenaar, M.A.; Hoekstra, O.S.; Berkhof, J.; Manoliu, R.A.; Teule, G.J.J.; Heyligers, I.C., 2004: A comparison of radiographic and scintigraphic techniques to assess aseptic loosening of the acetabular component in a total hip replacement. The diagnosis of a loose total hip prosthesis is often established with use of radiographic and nuclear medicine techniques, but there is controversy about the relative utility of plain radiography, subtraction arthrography, nuclear arthrography,...

Aliabadi, P.; Tumeh, S.S.; Weissman, B.N.; McNeil, B.J., 1989: Cemented total hip prosthesis: radiographic and scintigraphic evaluation. Conventional radiographs, technetium-99m bone scans, and gallium-67 scans were reviewed in 44 patients who had undergone cemented total hip joint replacement and were imaged because of suspicion of prosthesis loosening or infection. A complete rad...

Oyen, W.J.G.; Lemmens, J.A.M.; Claessens, R.A.M.J.; Van Horn, J.R.; Slooff, T.J.J.H.; Corstens, F.H.M., 1994: Nuclear arthrography Diagnosis of total hip prosthesis loosening. Journal of Nuclear Medicine 35(5 SUPPL ): 89P

Jacobsson, S.A.; Ivarsson, I.; Djerf, K.; Wahlström, O., 1995: Stem loosening more common with ITH than Lubinus prosthesis. A 5-year clinical and radiographic follow-up of 142 patients. Out of a consecutive series of 169 cemented total hip arthroplasties, 77 Lubinus SP 2 and 65 ITH prostheses, were followed-up after 5 years with clinical and radiographic assessments. Radiolucencies were commoner around the ITH titanium stem than...

Jacobsson, S.-Arne; Ivarsson, I.; Djerf, K.; Wahlstrom, O., 1995: Stem loosening more common with ITH than Lubinus prosthesis: A 5-year clinical and radiographic follow-up of 142 patients. Out of a consecutive series of 169 cemented total hip arthroplasties, 77 Lubinus SP 2 and 65 ITH prostheses, were followed-up after 5 years with clinical and radiographic assessments. Radiolucencies were commoner around the ITH titanium stem than...

Miyagi S., 1985: Application of sound transmission test of bone to diagnosis of loosening of total hip prosthesis. Orthopedic Surgery: 570-574