The effect of frequency change on discrimination of pulse bursts in an electrocutaneous tactual vocoder



The effect of frequency change on discrimination of pulse bursts in an electrocutaneous tactual vocoder



Journal of the Acoustical Society of America 77(3): 1192-1198



Tactual vacoders (artificial hearing sytems) transduce the acoustic energy of speech into patterns of stimulation that are presented to the skin. In an electrocutaneous tactual vocoder, energy within an acoustic-frequency band is generally represented at a particular skin locus by the rate or frequency of brief electrical pulse bursts. At present little is known about tactual sensitivity for changes in the frequency of brief, bipolar electrical pulses used in several current electrocutaneous vocoder designs. Accordingly, discrimination of frequency change of electrocutaneous bipolar signals was evaluated for standard frequencies of 48, 100, 148, 200 and 248 Hz at signal durations of 50, 100 and 250 ms. Bipolar pulses (height - 10 mA, width = 13 .mu.s) were presented on a single electrode placed slightly above and 8 cm to either the left or right of the navel. In a same-different task, 3 practiced subjects judged pairs of stimuli separated by an interstimulus interval (ISI) of 300 ms. For standard frequencies of 48 and 100 Hz, psychometric functions were similar for all subjects and all signal durations. For these frequencies, .DELTA. f/f [the Weber fraction] was constant at .apprx. 0.3. By contrast, for standard stimuli greater than 100 Hz, the Weber fraction increased dramatically as a function of both standard frequency and signal duration. In a 2nd, similar experiment the Weber fraction for a 248-Hz standard increased as ISI [interstimulus interval] was decreased below 300 ms. By contrast, ISI had little effect on sensitivity for standard stimuli of 48 and 100 Hz. Overall, these results suggest guidelines for possible intensity coding schemes for future electrocutaneous vocoder designs.

Please choose payment method:






(PDF emailed within 0-6 h: $19.90)

Accession: 006644243

Download citation: RISBibTeXText

PMID: 3156905

DOI: 10.1121/1.392184


Related references

Tactual perception of speech-like stimuli with an electrocutaneous vocoder. Artificial Organs 8(4): 494-497, 1984

Speech perception by congenitally deaf subjects using an electrocutaneous vocoder. Journal of Rehabilitation Research and Development 25(3): 41-50, 1988

Communication Of Speech Sounds By A Tactual Vocoder. Journal of Speech and Hearing Research 6: 207-222, 1963

Multisensory narrative tracking by a profoundly deaf subject using an electrocutaneous vocoder and a vibrotactile aid. Journal of Speech and Hearing Research 32(2): 331-338, 1989

Electric pulse frequency and magnitude of perceived sensation during electrocutaneous forearm stimulation. Archives of Physical Medicine and Rehabilitation 91(9): 1378-1382, 2010

The effects of vocoder filter configuration on tactual perception of speech. Journal of Rehabilitation Research and Development 26(4): 51-64, 1989

Maximum information transmission on a tactual vocoder--in the case of time-invariant stimulation. Iyo Denshi to Seitai Kogaku. Japanese Journal of Medical Electronics and Biological Engineering 17(3): 230-236, 1979

Infants' tactual discrimination of novel and familiar tactual stimuli. Child Development 50(4): 1251-1253, 1979

Temporal onset-order discrimination through the tactual sense: effects of frequency and site of stimulation. Journal of the Acoustical Society of America 120(1): 375-385, 2006

Pulse spacing in high-frequency atmospheric noise bursts. Journal of Geophysical Research 74(10): 2780-2782, 1969

Electrotactile two point discrimination as a function of frequency, pulse width and pulse time delay. Annals of Biomedical Engineering 6(2): 117-125, 1978

Effects of pulse height and pulse width on the magnitude sensation of electrocutaneous stimulus. Iyo Denshi to Seitai Kogaku. Japanese Journal of Medical Electronics and Biological Engineering 15(5): 315-320, 1977

Electrocutaneous pulse rate and pulse width psychometric functions for sensory communications. Human Factors 21(2): 241-249, 1979

Relationship between pulse rate and pulse width for a constant-intensity level of electrocutaneous stimulation. Annals of Biomedical Engineering 13(5): 373-383, 1985

Effect of unilateral brain injury in man on learning of a tactual discrimination. Journal of Comparative and Physiological Psychology 48(6): 478-481, 1955