The mackay marg tonometer part 7 the continuous registration of the intra ocular pressure


, : The mackay marg tonometer part 7 the continuous registration of the intra ocular pressure. Albrecht Von Graefes Archiv fuer Klinische und Experimentelle Ophthalmologie 198(2): 171-177

The Mackay-Marg-Tonometer continuously recorded the intraocular pressure [in man] as exactly as an electromanometer connected with the eye, provided that the corneal rigidity was eliminitated by a smooth indentation of the cornea by the tip of the probes. The deviation of the recorded values from linearity was considered, and the temperature of the probe was not influenced from outside.


Accession: 006712682

Submit PDF Full Text: Here


Submit PDF Full Text

No spam - Every submission is manually reviewed

Due to poor quality, we do not accept files from Researchgate

Submitted PDF Full Texts will always be free for everyone
(We only charge for PDFs that we need to acquire)

Select a PDF file:
Close
Close

Related references

Stepanik J., 1973: The mackay marg tonometer part 6 corneal rigidity and intra ocular pressure. Albrecht Von Graefes Archiv fuer Klinische und Experimentelle Ophthalmologie 188(3): 211-216

Stepanik, J., 1976: The Mackay-Marg-tonometer. VII. The continuous registration of the intraocular pressure. The Mackay-Marg-Tonometer registers continuously the intraocular pressure (Pt) as exactly as an electromanometer connected with the eye provided that the corneal rigidity is eliminitated by a smooth indentation of the cornea by the tip of the prob...

Stepanik, J., 1971: The Mackay-Marg tonometer. IV. Studies on the standard deviation of clinical measurements. Registration of pulsatory variations of the intraocular pressure. Albrecht Von Graefes Archiv für Klinische und Experimentelle Ophthalmologie. Albrecht Von Graefe's Archive for Clinical and Experimental Ophthalmology 183(1): 62-68

Sawada, A.; Koshiyama, H.; Takeda, T., 1969: Ocular tension in children measured with Mackay-Marg's tonometer. Nihon Ganka Kiyo 20(8): 781-783

Trux, E.; Follmann, P., 1969: Measurement of ocular tension in the newborn with the Mackay-Marg electronic tonometer. Bulletins et Memoires de la Societe Francaise D'ophtalmologie 82: 48-53

Moses, Robert A., 1966: Constant pressure applanatlon tonography with the Mackay-Marg tonometer. A method of constant pressure tonography is described. A variable weight Mackay-Marg applanation tonometer and servosystem are used to moitor intraocular [human] pressure and adjust this pressure to a present level. At given pressure and with know...

Stepanik, J., 1973: The Mackay-Marg-tonometer. VI. Corneal rigidity and intraocular pressure. Albrecht Von Graefes Archiv für Klinische und Experimentelle Ophthalmologie. Albrecht Von Graefe's Archive for Clinical and Experimental Ophthalmology 188(3): 211-216

Moses, R.A., 1966: Constant pressure applanation tonography with the Mackay-Marg tonometer. A method of constant pressure tonography is described. A variable weight Mackay-Marg applanation tonometer and servosystem are used to moitor intraocular [human] pressure and adjust this pressure to a present level. At given pressure and with know...

Tarkkanen, A.; Leikola, J., 1967: Postural variations of the intraocular pressure as measured with the Mackay-Marg tonometer. The intraocular pressures were measured in the 74 eyes of 37 young, healthy volunteers in different positions of the body by the Mackay-Marg tonometer. The procedure was started in the sitting position (+ 90 degrees) where 15-20 readings were made...

Miyagi, I., 1968: Measurements of ophthalmic (retinal) blood pressure by means of Mackay-Marg tonometer. Nippon Ganka Gakkai Zasshi 72(8): 1344-1353