Trial of an automatic coagulation tester electra 7000


, : Trial of an automatic coagulation tester electra 7000. Nouvelle Revue Francaise d'Hematologie 27(5): 313-320

The Electra 700, an automatic coagulation tester recently available in France, was investigated for its performance on routine tests: Quick's test, APTT, thrombin clotting time test, assay of fibrinogen and prothrombin complex factors. Reproducibility was exceptionally good for Quick's test (CV < 1%), excellent for the other tests (CV < 3%), acceptability of the various commercial reagents very good, and standard linearity excellent. There was close correlation with manually obtained (electromagnetic B.M.) or semiautomated (KC 10) results (0.9948 to 0.9345). The apparatus is entirely automatic once specimens have been loaded, and it is particularly adapted to dealing with long series of specimens (60 samples). Its original loading system makes it possible to carry out two types of test concurrently, as well as to insert emergency tests. Economically, the cost of disposables and reagent loss is satisfactory; however, all tests are carried out relatively slowly, though this is compensated for by the fact that the reactions are completely automatic.

(PDF 0-2 workdays service)

Accession: 006840505

Submit PDF Full Text: Here


Submit PDF Full Text

No spam - Every submission is manually reviewed

Due to poor quality, we do not accept files from Researchgate

Submitted PDF Full Texts will always be free for everyone
(We only charge for PDFs that we need to acquire)

Select a PDF file:
Close
Close

Related references

Cambus, J.P.; Biermé, R.; Martinou, J.C.; Dousset, B., 1985: Evaluation of the performance of an automatic coagulation tester: the Electra 700. The Electra 700, an automatic coagulation tester recently available in France, was investigated for its performance on routine tests: Quick's test, APTT, thrombin clotting time test, assay of fibrinogen and prothrombin complex factors. Reprod...

Genta, V.M.; Giella, P.; Wilson, C.L.; Dickinson, W.A.drew, J., 1996: Comparison of Coaguchek Plus-R and Hemochron Junior-R with Electra 1600C-R automatic coagulation analyzer. Clinical Chemistry 42(6 PART 2): S148

Knop, Daniel., 1999: 7000 mussels for 7000 islands Giant mussel renaturalization in the Philippines 7000 Muscheln fur 7000 Inseln Riesenmuschel-Renaturierung auf den Philippinen. DATZ. Mai; 525: 44-45

Thom, J.; Stoner, M.; Miotti, D.; Nicol, D., 1993: Evaluation of routine coagulation testing on the MLA Electra 1000c fully automated coagulation analyser. The MLA Electra 1000c is a fully automated coagulation analyser recently installed in our coagulation laboratory. Good correlation was found for prothrombin times (PTs) and activated partial thromboplastin times (aPTTs) between the automated and a...

Buxade, C.; Bergmann, J., 1972: Large-scale application of the Milko-Tester-Automatic and Milko-Tester III for photometric determination of milk fat content. Data from 4 Milko-Tester Automatic and 2 Milko-Tester III units at a milk analysis centre in Schleswig-Holstein, German Federal Republic, were used to assess their accuracy and efficiency under practical conditions. Fat content did not affect accu...

Kitamura, T., 1979: New electric dental pulp tester--digital automatic pulp tester by the Analytic Technology Company. Shikai Tenbo 54(6): 1045-1050

Kyla Siurola, A.L.; Antila, V., 1975: Experience of analytical testing with the Milko-Tester Automatic, Pro-Milk Automatic and IRMA. This paper was presented at a seminar on milk analysis in Stockholm on 7-8 Nov. 1974. Aspects discussed are the calibration of the instruments, reproducibility of results, accuracy of results compared with reference methods, the carry-over effect...

Mrowetz G., 1970: Studies on the fat determination of milk by means of automatic milko tester and milko tester iii. Milchwissenschaft: 265-274

Thomasow, J.M.owetz, G., 1970: Studies on the fat determination of milk by means of Milko Tester Automatic and Milko Tester III. Milchwissenschaft 25 (5) 265-274

Thomasow, J.; Mrowetz, G., 1970: Studies on the fat determination of milk by Milko-tester Automatic and Milko-tester III. Both testers were found to yield accurate and reproducible results for the fat in milk in the 2-8% range; above the latter value dilution of the sample before testing is recommended and above 9.99% fat it is necessary. Accuracy was much superior t...