Continuous monitoring of mixed venous oxygen saturation during exercise using fiberoptic pulmonary artery catheter



Continuous monitoring of mixed venous oxygen saturation during exercise using fiberoptic pulmonary artery catheter



Kokyu to Junkan. Respiration & Circulation 38(8): 799-804



We measured the mixed venous oxygen saturation (S.hivin.vO2) continuously using a fiberoptic thermodilution pulmonary artery catheter to analyze the time course of S.hivin.vO2 during exercise, and evaluated the relationship between S.hivin.vO2 and exercise load, S.hivin.VO2 and cardiac output. Five patients with old myocardial infarction and one healthy man underwent pulmonary arterial catheterization and then performed an incremental steady state exercise test using a supine cycle ergometer. There was a rapid fall in S.hivin.vO2 43.4 .+-. 10.6 seconds after the start of exercise and new steady state were achieved 92.6 .+-. 22.5 seconds after changing the exercise load. The value of S.hivin.vO2 at exercise load 60 watts were 44.7 .+-. 9.8% and this value was under the level of lactic acid accumulation. S.hivin.vO2 correlates well with cardiac output by the thermodilution method in individual patients. We conclude that a fiberoptic thermodilution pulmonary artery catheter was useful to evaluate the dynamic changes of S.hivin.vO2 during exercise.

Please choose payment method:






(PDF emailed within 1 workday: $29.90)

Accession: 007156279

Download citation: RISBibTeXText

PMID: 2218089


Related references

Predictive factors for usefulness of fiberoptic pulmonary artery catheter for continuous oxygen saturation in mixed venous blood monitoring in cardiac surgery. Anesthesia and Analgesia 85(1): 2, 1997

The accuracy of the continuous mixed venous oxygen saturation pulmonary artery catheter during cardiac surgery. Anesthesiology 71(3A): A382, 1989

Evaluation of A 85 French fiberoptic catheter for continuous monitoring of cerebral venous oxygen saturation. Acta Anaesthesiologica Scandinavica 37(Suppl. 100): 219, 1993

Continuous Fick cardiac output measurement during exercise by monitoring of mixed venous oxygen saturation and oxygen uptake. Chest 104(2): 419-426, 1993

Does continuous monitoring of mixed venous oxygen saturation accurately reflect oxygen delivery and oxygen consumption following coronary artery bypass grafting?. Surgical Forum (Chicago) 37: 66-68, 1986

Evaluation of a 7.5 French pulmonary catheter for continuous monitoring of cerebral venous oxygen saturation. Journal of Neurosurgical Anesthesiology 6(4): 233-238, 1994

Continuous monitoring of mixed venous oxygen saturation in anesthesia in pulmonary surgery. Annales Francaises d'Anesthesie et de Reanimation 8(6): 682-687, 1989

Evaluation of a new fiberoptic catheter for monitoring jugular venous oxygen saturation. Neurosurgery 44(6): 1280-1285, 1999

Continuous monitoring of the central venous oxygen saturation in surgical patients: comparison to the monitoring of the mixed venous saturation. Acta Anaesthesiologica Scandinavica 40(8 Pt 1): 956, 1996

Continuous central venous and pulmonary artery oxygen saturation monitoring in the critically ill. Intensive Care Medicine 30(8): 1572-1578, 2004

Longterm accuracy of continuous fiberoptic venous oxygen saturation monitoring. Anesthesiology 73(3A): A495, 1990

Comparison of mixed venous oxygen saturation after in vitro calibration of pulmonary artery catheter with that of pulmonary arterial blood in patients undergoing living donor liver transplantation. Transplantation Proceedings 45(5): 1916-1919, 2013

Fiberoptic monitoring of central venous oxygen saturation (PediaSat) in small children undergoing cardiac surgery: continuous is not continuous. F1000research 3: 23, 2014

Mixed Venous Oxygen Saturation Measured with an Abbot Oximetric Pulmonary Artery Catheter, and Instrumentation Laboratory Co-Oximeter after Resuscitation with Varying Concentrations of Hemoglobin-Based Oxygen Carrier in a Dog Hemorrhage Model. Anesthesiology Abstracts of Scientific Papers Annual Meeting (2001): Abstract No A-556, 2002

A case of monolateral pulmonary pathology treated with independent lung ventilation continuous monitoring of mixed venous oxygen saturation. Minerva Anestesiologica 57(12 Suppl): 93-96, 1991