Reflectance pulse oximetry in fetal lambs



Reflectance pulse oximetry in fetal lambs



Pediatric Research 31(3): 266-269



Transmission pulse oximetry is used for monitoring in many clinical settings. However, for fetal monitoring during labor and in situations with poor peripheral perfusion, transmission pulse oximetry cannot be used. Therefore, we developed a reflectance pulse oximeter, which uses the relative intensity changes of the reflected red and infrared light (red/infrared ratio) to measure the arterial oxygen saturation. The performance of the reflectance pulse oximeter was studied in acute experiments in fetal lambs. By stepwise reduction of the inspired oxygen concentration of the ewe, measurements were done at the fetal scalp at various arterial oxygen saturation levels (17-82%). Reflectance pulse oximeter reading were averaged over periods of 15 s and compared with simultaneously taken fetal arterial blood samples. A calibration curve for the relationship between red/infrared ratio and arterial oxygen saturation was obtained from 53 measurements in four fetal lambs, by linear regression analysis [red/infrared = 4.088 - (0.038) .cntdot. SaO2), r = 0.96]. In these experiments the pulse oximeter showed a precision of 4.7% oxygen saturation around the calibration curve, with a 95% confidence interval of .+-. 9.4%.

(PDF emailed within 0-6 h: $19.90)

Accession: 007731421

Download citation: RISBibTeXText

PMID: 1561013

DOI: 10.1203/00006450-199203000-00014



Related references

Reflectance pulse oximetry: accuracy of measurements from the neck of fetal lambs. Advances in Experimental Medicine and Biology 388: 69-75, 1996

Reflectance pulse oximetry in fetal lambs: subcutaneous vessels and vasoconstriction affect its reliability. Journal of Clinical Monitoring 12(3): 225-230, 1996

Multicenter study on the clinical value of fetal pulse oximetry. II. Compared predictive values of pulse oximetry and fetal blood analysis. The French Study Group on Fetal Pulse Oximetry. American Journal of Obstetrics and Gynecology 177(3): 593-598, 1997

Fetal reflectance pulse oximetry during labour. Zeitschrift fuer Geburtshilfe und Perinatologie 198(2): 67-71, 1994

Altmetrics: Beyond the Impact Factor. Actas Dermo-Sifiliograficas, 2018

How well does reflectance pulse oximetry reflect intrapartum fetal acidosis?. American Journal of Obstetrics & Gynecology 186(6): 1351-1357, June, 2002

The effect of meconium on neonatal and fetal reflectance pulse oximetry. Journal of Perinatal Medicine 18(5): 351-355, 1990

The accuracy of transmission pulse oximetry in fetal lambs. Journal of Physiology (Cambridge) 479P(0): 20P, 1994

Application of transmission and reflection pulse oximetry in fetal lambs. Lafeber, H N (Ed ) International Congress Series, No 967 Fetal And Neonatal Physiological Measurements; 4th International Conference, Noordwijkerhout, Netherlands, May 12-15, X+327p Elsevier Science Publishers B V : Amsterdam, Netherlands; (Dist in The Usa And Canada By Elsevier Science Publishing Co , Inc : New York, New York, Usa) Illus 123-128, 1991

Effects of maternal oxygen administration on fetal pulse oximetry measured by fetal pulse oximetry. American Journal of Obstetrics and Gynecology 196(4): E13; Author Reply E13-E13; Author Reply E13, 2007

Fetal reflectance pulse oximetry sub partu. Experiences--prognostic significance and consequences--goals. Zeitschrift für Geburtshilfe und Perinatologie 198(2): 67-71, 1994

Clinical importance of fetal pulse oximetry. I. Methodological evaluation. Multicenter study. French Study Group on Oximetry of Fetal Pulse. Journal de Gynecologie, Obstetrique et Biologie de la Reproduction 28(1): 31-40, 1999

Multicenter study on the clinical value of fetal pulse oximetry. I. Methodologic evaluation. The French Study Group on Fetal Pulse Oximetry. American Journal of Obstetrics and Gynecology 177(5): 1238-1246, 1997

The feasibility of spectrophotometric measurements of arterial oxygen saturation from the fetal scalp utilizing noninvasive skin-reflectance pulse oximetry. Biomedical Instrumentation & Technology 26(3): 215-224, 1992

Calibration of a reflectance pulse oximeter in fetal lambs for arterial oxygen saturations below 70%. Journal of the Society for Gynecologic Investigation 5(5): 255-259, 1998