+ Site Statistics
+ Search Articles
+ PDF Full Text Service
How our service works
Request PDF Full Text
+ Follow Us
Follow on Facebook
Follow on Twitter
Follow on LinkedIn
+ Subscribe to Site Feeds
Most Shared
PDF Full Text
+ Translate
+ Recently Requested

A collaborative European study of personal inhalable aerosol sampler performance



A collaborative European study of personal inhalable aerosol sampler performance



Annals of Occupational Hygiene 41(2): 135-153



Following the adoption of new international sampling conventions for inhalable, thoracic and respirable aerosol fractions, a working group of Comité Européen de Normalisation (CEN) drafted a standard for the performance of workplace aerosol sampling instruments. The present study was set up to verify the experimental, statistical and mathematical procedures recommended in the draft performance standard and to check that they could be applied to inhalable aerosol samplers. This was achieved by applying the tests to eight types of personal inhalable aerosol sampler commonly used for workplace monitoring throughout Europe. The study led to recommendations for revising the CEN draft standard, in order to simplify the tests and reduce their cost. However, some further work will be needed to develop simpler test facilities and methods. Several of the samplers tested were found to perform adequately with respect to the inhalable sampling convention, at least over a limited range of typical workplace conditions. In general the samplers were found to perform best in low external wind speeds, which are the test conditions thought to be closest to those normally found in indoor workplaces. The practical implementation of the CEN aerosol sampling conventions requires decisions on which sampling instruments to use, estimation of the likely impact that changing sampling methods could have on apparent exposures, and adjustment where necessary of exposure limit values. The sampler performance data obtained in this project were affected by large experimental errors, but are nevertheless a useful input to decisions on how to incorporate the CEN inhalable sampling convention into regulation, guidance and occupational hygiene practice.

Please choose payment method:






(PDF emailed within 0-6 h: $19.90)

Accession: 008028577

Download citation: RISBibTeXText

PMID: 9155236

DOI: 10.1016/s0003-4878(96)00034-8


Related references

A Collaborative European Study Of Personal Inhalable Aerosol Sampler Performance. Annals of Occupational Hygiene 41(2): 135-153, 1997

Performance characteristics of the button personal inhalable aerosol sampler. Aihaj 61(3): 398-404, 2000

Performance evaluation of disposable inhalable aerosol sampler at a copper electrorefinery. Journal of Occupational and Environmental Hygiene 16(3): 250-257, 2019

Performance of personal inhalable aerosol samplers in very slowly moving air when facing the aerosol source. Annals of Occupational Hygiene 48(4): 351-368, 2004

Performance of the Button Personal Inhalable Sampler for the measurement of outdoor aeroallergens. Atmospheric Environment 37(34): 4723-4733, 2003

Correlation between urinary 1-hydroxypyrene and ambient air pyrene measured with an inhalable aerosol sampler and a total dust sampler in an electrode paste plant. Science of the Total Environment 212(1): 59-67, 1998

A personal sampler for inhalable mixed-phase aerosols: Modification to an existing sampler and validation test with three pesticides. Chemosphere 28(6): 1135-1146, 1994

Evaluation of the use of an SKC button inhalable aerosol sampler with a Grimm aerosol monitor to determine air concentrations of subtilisin. Journal of Chemical Health and Safety 21(6): 4-13, 2014

Performance study of personal inhalable aerosol samplers at ultra-low wind speeds. Annals of Occupational Hygiene 56(2): 207-220, 2012

A Simple and Disposable Sampler for Inhalable Aerosol. Annals of Occupational Hygiene 60(2): 150-160, 2016

Use of Numerical Calculations to Simulate the Sampling Efficiency Performance of a Personal Aerosol Sampler. Aerosol Science & Technology 39(7): 596-610, 2005

Performance of the RespiCon personal aerosol sampler in forest products industry workplaces. Aiha Journal 63(3): 311-316, 2002

A field comparison of the IOM inhalable aerosol sampler and a modified 37-mm cassette. Applied Occupational and Environmental Hygiene 17(9): 622-627, 2002

Evaluation of the respicon as a personal inhalable sampler in industrial environments. Journal of Environmental Monitoring 4(5): 657-662, 2002

Assessment of increased sampling pump flow rates in a disposable, inhalable aerosol sampler. Journal of Occupational and Environmental Hygiene 14(3): 207-213, 2017