Bremsstrahlung production at 50 MeV in different target materials and configurations



Bremsstrahlung production at 50 MeV in different target materials and configurations



Medical Physics 23(4): 495-503



A combination of Monte Carlo, convolution, and experimental techniques have been used to investigate bremsstrahlung production at 50 MeV in full-range targets to produce narrow elementary photon beams for scanning. Calculations using the ITS 3.0 Monte Carlo system for various target designs, including particle transport through the treatment head of an MM50 racetrack microtronn and a water phantom, have been compared to experimental dose profiles from narrow photon beams at 10-cm depth in water. A reduction in the ITS 3.0 default substep size has been found necessary even for incomplete agreement, in consistency with the findings of Faddegon and Rogers (Nucl. Instrum. Meth. A 327, 556-565 (1993)) for a different experimental setup and energy using the previous version of ITS. Results show that the calculated shape of the tail of dose distributions from narrow photon beams agrees well with measurements, but CYLTRAN/ITS 3.0 fails to reproduce the central part of the distribution. The discrepancy at small angles, reported previously for EGS4 and ITS 2.1 simulations, possess a limitation to Monte Carlo simulations of narrow photon beams used in scanned systems of clinical accelerators. Radial dose profiles have been calculated by convolution of the energy fluence at the exit of the target with one polyenergetic Monte Carlo calculated dose kernel and also a database consisting of ten different dose kernels corresponding to different monoenergetic photon pencil beams for comparison. The agreement with the much slower fully detailed Monte Carlo calculations was better when using the database kernels than the polyenergetic kernel. Results for the mean energy, mean polar angle, and energy fluence at different depths within various targets have been obtained. These are discussed in the context of the design characteristics of bremsstrahlung targets with emphasis on their utilization for scanning photon beam techniques.

(PDF emailed within 0-6 h: $19.90)

Accession: 008245698

Download citation: RISBibTeXText

PMID: 9157260

DOI: 10.1118/1.597681



Related references

A survey of target materials and orientations suitable for the production of coherent bremsstrahlung in megavoltage imaging. Physics in Medicine and Biology 57(8): 2411-2423, 2012

Role of polarization Bremsstrahlung in the formation of thick target Bremsstrahlung spectra in the energy range of 5–1?keV. 2012

Bremsstrahlung production from a linac target in the presence of external magnetic fields. Australasian Physical & Engineering Sciences in Medicine 21(3): 120-125, 1998

Target self-attenuation extension to the Desobry and Boyer thick-target bremsstrahlung spectrum. Medical Physics 21(4): 577-579, 1994

Selection of target and target cladding materials for isotope production at the los alamos meson physics facility. Journal of Nuclear Medicine 19(6): 687, 1978

Polarized-target asymmetry in pion-proton bremsstrahlung at 298 MeV. Physical Review Letters 64(22): 2619-2622, 1990

Experimental thick-target bremsstrahlung spectra from collisions of 7.0-keV electrons with Ag and Au. Physical Review. A, Atomic, Molecular, and Optical Physics 54(3): 2056-2059, 1996

Thick-target external-bremsstrahlung spectra of 147Pm and 35S beta rays. Physical Review. A, Atomic, Molecular, and Optical Physics 48(2): 1308-1312, 1993

Experimental investigation of thick target bremsstrahlung radiation produced by electrons of 1.00, 1.50 and 2.00 MeV. Health Physics 4: 1-15, 1960

Calculation of depth dose curves in water due to thick target bremsstrahlung. Medical Physics (Woodbury) 2(3): 165, 1975

A verification of the Monte Carlo code MCNP for thick target bremsstrahlung calculations. Medical Physics 22(1): 11-16, 1995

Thick-target bremsstrahlung spectra generated by the beta particles of 90Sr-90Y and 99Tc. Physical Review. A, General Physics 34(6): 5126-5129, 1986

Target materials for the cyclotron production of carrier free bromine 77. International Journal of Applied Radiation & Isotopes 26(12): 731-735, 1975

Instrumental neutron-activation determination of phosphorus in biological materials by bremsstrahlung measurement. Talanta 35(10): 747-751, 1988

Spatial distribution of energy transfer from thick target bremsstrahlung measured with miniature dosimeter. Health Physics 33: 479-481, 1977