Clinical application of a newly developed autoflow control system for the Terumo centrifugal pump: From external control to built-in direct control



Clinical application of a newly developed autoflow control system for the Terumo centrifugal pump: From external control to built-in direct control



Artificial Organs 20(6): 625-631



We have developed an autoflow control system for the Terumo Capiox centrifugal pump, the SP-101. First, we made an external control system regulated by a personal computer through a serial communications line. Although an in vivo experiment using a goat showed excellent performance in regulating the flow, a communication error that caused an abrupt and instantaneous flow fluctuation was noted occasionally. Therefore, we incorporated a check-sum function to solve this problem. After this improvement, 5 patients safely underwent cardiopulmonary bypass using a pump having this autoflow control. As the next step for more practical usage, we developed a built-in autoflow control system in which the control device is entirely incorporated into the console without a communications line. This system demonstrated better response and reliability than the external control system and was applied successfully in 3 patients. In conclusion, this autoflow mode will expand the usage of centrifugal pumps through improved handling.

Please choose payment method:






(PDF emailed within 0-6 h: $19.90)

Accession: 008324277

Download citation: RISBibTeXText

PMID: 8817968

DOI: 10.1111/j.1525-1594.1996.tb04493.x


Related references

Clinical application of a newly developed built-in type autoflow control system for Terumo Centrifugal Pump. Japanese Journal of Artificial Organs 25(2): 365-370, 1996

Development of an autoflow control system for a centrifugal pump. Japanese Journal of Artificial Organs 24(2): 608-612, 1995

Development of an autoflow cruise control system for a centrifugal pump. Artificial Organs. : 713-718, 1995

Clinical application of the straight path Terumo Capiox centrifugal pump A comparative study with the roller pump. Japanese Journal of Artificial Organs 22(3): 935-938, 1993

Development of the terumo capiox centrifugal pump and its clinical application to open heart surgery: A comparative study with the roller pump. Artificial Organs 17(5): 323-327, 1993

Influences of newly developed centrifugal pump driving on platelet and coagulation and fibrinolysis system. Japanese Journal of Artificial Organs 22(3): 650-653, 1993

Newly developed blood pump and control unit for neonatal extracorporeal membrane oxygenation. Japanese Journal of Artificial Organs 23(1): 328-331, 1994

The Internal Control Index: A Newly Developed Measure of Locus of Control. Educational and Psychological Measurement 44(2): 209-221, 1984

Study on external quality control program in clinical pathology in Japan Review of quality control program for clinical microbiology developed by the Tokyo metropolitan government. Nichidai Igaku Zasshi 52(5): 239-241, 1993

Clinical evaluation of pulsatile flow mode of Terumo Capiox centrifugal pump. Artificial Organs. 21(7): 816-821, 1997

Automatic control system of centrifugal pump flow based on the motor current. Japanese Journal of Artificial Organs 27(1): 37-40, 1998

Modeling and control of a magnetic bearing system for the magnetically suspended centrifugal blood pump. International Journal of Artificial Organs 23(10): 689-696, 2000

Modeling and Control of a Magnetic Bearing System for the Magnetically Suspended Centrifugal Blood Pump. The International Journal of Artificial Organs 23(10): 689-696, 2000

Development of a flow estimation and control system of an implantable centrifugal blood pump for circulatory assist. Artificial Organs. 22(6): 488-492, E, 1998

Clinical evaluation of pulsatile flow mode of Terumo Capiox Centrifugal Pump: A comparative study with Sarns Delphin pump and internal mode driving of intraaortic balloon pumping. Japanese Journal of Artificial Organs 26(1): 81-85, 1997