Determination of naringin in grapefruit juice by cathodic stripping differential pulse voltammetry at the hanging mercury drop electrode



Determination of naringin in grapefruit juice by cathodic stripping differential pulse voltammetry at the hanging mercury drop electrode



Analytica Chimica Acta 360(1-3): 179-187, Ch 10



A highly sensitive cathodic stripping voltammetric method for the determination of naringin is presented. It is based on the formation and accumulation of two naringin-mercury complexes at the electrode surface, followed by reduction of the surface species during a differential pulse voltammetric scan. The cathodic stripping responses at -0.25 V and -0.42 V, are evaluated with respect to various experimental conditions, such as composition and pH of the supporting electrolyte, naringin concentration, accumulation potential and preconcentration time. The new method is suitable for the determination of naringin concentrations between 0.1 mg l-1 (1.72 X 10-7 mol l-1) and 40 mg l-1 (6.88 X 10-5 mol l-1). A 3sigma limit of detection of 32 mug l-1 (55 nmol l-1) can be reached. The relative standard deviation (r.s.d.) is <1.5%. Recovery experiments yielded a mean recovery of 97% (r.s.d.=4.1%). The application of the procedure to the selective determination of naringin in grapefruit juice is demonstrated.

Please choose payment method:






(PDF emailed within 0-6 h: $19.90)

Accession: 008446824

Download citation: RISBibTeXText

DOI: 10.1016/s0003-2670(97)00704-6


Related references

Differential pulse cathodic stripping voltammetry of the copper complexes of glycyl-L-histidyl-glycine at a hanging mercury drop electrode. Talanta 40(10): 1481-1488, 1993

Simultaneous determination of Cd, Pb, Cu, Sb, Bi, Se, Zn, Mn, Ni, Co and Fe in water samples by differential pulse stripping voltammetry at a hanging mercury drop electrode. Fresenius' Journal of Analytical Chemistry 367(4): 378-383, 2000

Determination of arsenic by cathodic stripping voltammetry at a hanging mercury drop electrode. Microchimica Acta 111(1-3): 55-62, 1993

Determination of trace amounts of bacitracin by differential pulse adsorptive stripping voltammetry at a hanging mercury drop electrode. Analytical Proceedings 28(1): 16-20, 1991

Determination of Zn, Cd, Pb, Cu, Sb and Bi in milk by differential pulse anodic stripping voltammetry with a hanging mercury drop electrode following two independent mineralisation methods. Analusis 13(10): 471-473, 1985

Trace zinc determination in acid media by differential pulse anodic stripping voltammetry at a hanging drop mercury electrode. Analytical Chemistry 48(4): 759-761, 1976

Determination of As and arsenic in natural waters by cathodic stripping voltammetry at a hanging mercury drop electrode. Analytica Chimica Acta 459(1): 151-159, 2002

Determination of paraquat by cathodic stripping voltammetry after accumulation through the formation of an ion pair on a hanging mercury drop electrode. Electroanalysis 5(1): 79-83, 1993

Studies of pretreatments in the determination of Zn, Cd, Pb, Cu, Sb and Bi in suspended particulate matter and plankton by differential-pulse anodic-stripping voltammetry with a hanging mercury drop electrode. Talanta 29(8): 651-654, 1982

Imprinted polymer-modified hanging mercury drop electrode for differential pulse cathodic stripping voltammetric analysis of creatine. Biosensors and Bioelectronics 22(12): 3302-3308, 2007

Direct and simultaneous determinations of Zn, Cd, Pb, Cu, Sb and Bi dissolved in sea water by differential pulse anodic stripping voltammetry with a hanging mercury drop electrode. Analytica Chimica Acta 106(1): 23-37, 1979

Cathodic stripping voltammetry of orotic acid vitamin b 13 at the hanging mercury drop electrode hmde. Fresenius Zeitschrift fuer Analytische Chemie 330(2): 146-148, 1988

Catalytic cathodic stripping voltammetry of oxidized glutathione at a hanging mercury drop electrode in the presence of nickel ion. Talanta 42(2): 227-234, 1995

Cathodic stripping voltammetry of technetium in the tetraphenylarsonium chloride chloroform extract at a hanging mercury drop electrode. Journal of Radioanalytical and Nuclear Chemistry 141(1): 179-184, 1990

Implementation of a differential pulse anodic stripping voltammetry (DPASV) at a hanging mercury drop electrode (HMDE) procedure for the analysis of airborne heavy metals. Analytical Letters 34(13): 2349-2360, 2001