+ Site Statistics
References:
54,258,434
Abstracts:
29,560,870
PMIDs:
28,072,757
+ Search Articles
+ PDF Full Text Service
How our service works
Request PDF Full Text
+ Follow Us
Follow on Facebook
Follow on Twitter
Follow on LinkedIn
+ Subscribe to Site Feeds
Most Shared
PDF Full Text
+ Translate
+ Recently Requested

Evaluation of lanthanide tracer methods in the study of mammalian pulmonary parenchyma and cardiac muscle by electron energy-loss spectroscopy



Evaluation of lanthanide tracer methods in the study of mammalian pulmonary parenchyma and cardiac muscle by electron energy-loss spectroscopy



Journal Of Microscopy (oxford). 174(3): 207-223



Lanthanum (La) has widely been used as a tracer to study the integrity of plasma membranes. With conventional transmission electron microscopy (cTEM), the absence of electron scattering deposits from the cytoplasm has generally been assumed to reflect an intact cell membrane. However, the application of electron spectroscopic imaging (ESI) and electron energy-loss spectroscopy (EELS) reveals that electron scattering deposits may be present which do not contain La. However, La could be detected in regions of pulmonary parenchyma and cardiac muscle that were devoid of electron scattering deposits. Therefore, to exclude misinterpretations based on cTEM the application of microanalytical techniques is strongly recommended for the study of the integrity of plasma membranes by means of La tracers. In addition, ESI and EELS are shown to distinguish between different tracers in simultaneous applications of La and terbium (Tb) which were used at the different faces of the pulmonary air-blood barrier. The analysis of the distribution of both tracers which form electron scattering deposits, indistinguishable by cTEM, may help us to understand the different functional significances of cellular alterations of both cellular borders of the barrier. As was shown for La, however, strictly controlled conditions are mandatory during the fixation procedure because an increase in the incubation time to more than 1 h in samples of pulmonary parenchyma may result in the occurrence of La deposits within the cytoplasm. In the absence of electron scattering deposits, the presence of La in glycogen granules and ribosome-containing areas of various types of alveolar septal cells even after 15 min incubation indicates that the absence of deposits does not necessarily correspond to the absence of the tracer.

Please choose payment method:






(PDF emailed within 0-6 h: $19.90)

Accession: 008634846

Download citation: RISBibTeXText

PMID: 8071989

DOI: 10.1111/j.1365-2818.1994.tb03468.x


Related references

Allium cepa root tip assay in assessment of toxicity of magnesium oxide nanoparticles and microparticles. Journal of Environmental Sciences 66: 125-137, 2018

Fluorinated molecule as a tracer: difluoroserotonin in human platelets mapped by electron energy-loss spectroscopy. Science 200(4341): 537-539, 1978

Onset of oxidation of Al(111) at low temperatures: A study by electron-energy-loss spectroscopy and Auger electron spectroscopy. Physical Review. B, Condensed Matter 33(2): 1436-1439, 1986

Parallel electron energy-loss spectroscopy (PEELS) study of B in minerals; the electron energy-loss near-edge structure (ELNES) of the B K edge. American Mineralogist 80(11-12): 1132-1144, 1995

Application of electron energy-loss spectroscopy EELS and energy-filtered transmission electron microscopy EFTEM to the study of mineral transformation associated with microbial Fe-reduction of; magnetite. Clays and Clay Minerals 59.2, 2011

Demonstration of lanthanum in liver cells by energy-dispersive X-ray spectroscopy, electron energy loss spectroscopy and high-resolution transmission electron microscopy. Journal of Microscopy 223(Pt 2): 133-139, 2006

Two-dimensional boundary conditions and finite-size effects in angle-resolved photoelectron emission spectroscopy, low-energy electron diffraction, and high-resolution electron-energy-loss spectroscopy. Physical Review. B, Condensed Matter 37(6): 2884-2891, 1988

Sub-cellular localization of manganese in the basal ganglia of normal and manganese-treated rats An electron spectroscopy imaging and electron energy-loss spectroscopy study. Neurotoxicology 29(1): 60-72, 2007

Auger-electron spectroscopy, electron-energy-loss spectroscopy, and x-ray photoemission spectroscopy studies of oxygen adsorption on the InP(111)-(1 x 1) surface. Physical Review. B, Condensed Matter 43(6): 4803-4808, 1991

Theoretical study of core-loss electron energy-loss spectroscopy at graphene nanoribbon edges. Journal of Physics. Condensed Matter 27(30): 305301-305301, 2015

Electron microscopy and electron energy-loss spectroscopy study of Nd 1-x Sr x CoO 3-δ (0 ≤ x ≤ 1) system. Microscopy and Microanalysis 20(3): 687-691, 2014

The applications of in situ electron energy loss spectroscopy to the study of electron beam nanofabrication. Microscopy and Microanalysis 15(3): 204-212, 2009

High resolution ultrastructural mapping of total calcium: Electron spectroscopic imaging/electron energy loss spectroscopy analysis of a physically/chemically processed nerve-muscle preparation. Proceedings of the National Academy of Sciences of the United States of America 93(10): 4799-4803, 1996

Electronic excitations of the YBa2Cu3O7-x superconductor: A study by transmission electron-energy-loss spectroscopy with an electron microprobe. Physical Review. B, Condensed Matter 37(16): 9780-9783, 1988