EurekaMag.com logo
+ Site Statistics
References:
53,869,633
Abstracts:
29,686,251
+ Search Articles
+ Subscribe to Site Feeds
EurekaMag Most Shared ContentMost Shared
EurekaMag PDF Full Text ContentPDF Full Text
+ PDF Full Text
Request PDF Full TextRequest PDF Full Text
+ Follow Us
Follow on FacebookFollow on Facebook
Follow on TwitterFollow on Twitter
Follow on LinkedInFollow on LinkedIn

+ Translate

Fetal pulse oximetry and fetal heart rate monitoring during stage II of labour



Fetal pulse oximetry and fetal heart rate monitoring during stage II of labour



European Journal Of Obstetrics & Gynecology & Reproductive Biology. 72(suppl.): S57-S61



Objective: This study was designed to assess the changes in fetal oxygen saturation (FSpo-2) using fetal pulse oximetry when the fetal heart rate (FHR) monitoring became abnormal during stage II of labour. Study design: FSpo-2 was recorded with the Nellcor N400 Oximeter (FS-14 sensor) and was averaged over the last 10 min of the second stage of labour. Second stage FHR patterns were assessed according to Melchior's classification. Results: In terms of FHR patterns, FSpo-2-10" measured 41.4% in type 0 (n = 5), 42.4% in type 1 (n = 19), 43.3% in type 2 (n = 6), 34.0% in type 3 (n = 4) and 27.6% in type 4 (n = 7) (P = 0.03). Conclusions: FSpo-2-10" decreases in cases of severe FHR abnormality during the second stage of labour and could help to decide whether to perform an instrumental extraction.

(PDF emailed within 0-6 h: $19.90)

Accession: 008683546

Download citation: RISBibTeXText

PMID: 9134414

DOI: 10.1016/s0301-2115(97)02719-x



Related references

Reduction in caesarean delivery with fetal heart rate monitoring and intermittent pulse oximetry after induction of labour with misoprostol. Journal of Maternal-Fetal & Neonatal Medicine 22(5): 445-451, 2009

Computerised intrapartum diagnosis of fetal hypoxia based on fetal heart rate monitoring and fetal pulse oximetry recordings utilising wavelet analysis and neural networks. Bjog 109(10): 1137-1142, 2002

Fetal pulse oximetry: an adjunct to electronic fetal heart rate monitoring. Journal of Obstetric, Gynecologic, and Neonatal Nursing 29(5): 537-548, 2000

Correlation of fetal oxygen saturation to fetal heart rate patterns: Evaluation of fetal pulse oximetry with two different oxisensors. Acta Obstetricia et Gynecologica Scandinavica 77(3): 307-312, 1998

Multicenter study on the clinical value of fetal pulse oximetry. II. Compared predictive values of pulse oximetry and fetal blood analysis. The French Study Group on Fetal Pulse Oximetry. American Journal of Obstetrics and Gynecology 177(3): 593-598, 1997

Fetal pulse oximetry, pathological heart rate and fetal hypoxia during labor. Fetal Diagnosis & Therapy 13(SUPPL 1): 118, 1998

Intrapartum fetal pulse oximetry and fetal heart rate decelerations. International Journal of Gynaecology and Obstetrics: the Official Organ of the International Federation of Gynaecology and Obstetrics 85(1): 12-17, 2004

Fetal pulse oximetry in intrapartum management of nonreassuring fetal heart rate patterns. American Journal of Obstetrics and Gynecology 185(3): 771-772, 2001

Fetal pulse oximetry: correlation with intrapartum fetal heart rate patterns and neonatal outcome. Journal of Obstetrics and Gynaecology Research 34(5): 824-831, 2008

Fetal pulse oximetry and wavelet analysis of the fetal heart rate in the evaluation of abnormal cardiotocography tracings. Journal of Obstetrics and Gynaecology Research 32(2): 135-139, 2006