Impedance spectra of tumour tissue in comparison with normal tissue: A possible clinical application for electrical impedance tomography



Impedance spectra of tumour tissue in comparison with normal tissue: A possible clinical application for electrical impedance tomography



Physiological Measurement 17(SUPPL. 4A): A105-A115



Electrical characteristics of living tissues have been investigated for a long time in the search for further methods to complement the traditional investigations of pathology and physiology. Tumour tissue has been shown to exhibit a larger permittivity and conductivity than normal tissues. This might be associated with the fact that tumour cells have a higher water content and sodium concentration than normal cells, as well as different electrochemical properties of their cell membranes. To our knowledge only a few contributions on this subject have been published. This study describes an additional application on measurements of the complex impedance of turnout and normal tissues, in order to compare the impedance features of the two tissue types. The tissue sample is placed in a measuring cell in which the temperature is controlled. The measuring cell is connected to an impedance meter able to measure the complex impedance in terms of real and imaginary part curves for frequencies from 1.5 kHz to 700 kHz. The four-electrode principle is used with the current injected by the outer electrodes and the voltage difference measured between the inner electrodes. The current can be altered up to 1 mA. The instrument can be calibrated with known resistance and capacitance networks connected to the input of the instrument in order to minimize the measurement errors. The calibration routine uses a polynomial adaptation and can be applied interactively. Measurements performed by the instrument show promising results. Preliminary results show that this method can be extended to a new application for detection of tumour tissue by electrical impedance tomography (EIT).

(PDF emailed within 0-6 h: $19.90)

Accession: 008828657

Download citation: RISBibTeXText

PMID: 9001609

DOI: 10.1088/0967-3334/17/4A/015



Related references

Comparative study of separation between ex vivo prostatic malignant and benign tissue using electrical impedance spectroscopy and electrical impedance tomography. Physiological Measurement 38(6): 1242-1261, 2017

Electrical impedance spectroscopy (EIS)-based evaluation of biological tissue phantoms to study multifrequency electrical impedance tomography (Mf-EIT) systems. Journal of Visualization 19(4): 691-713, 2016

Electrical impedance tomography. Determination of impedance of tissue in the frequency range 10(-6)-20 MHz: preliminary results. Clinical Physics and Physiological Measurement 13 Suppl A: 73-75, 1992

Electrical impedance tomography of cell viability in tissue with application to cryosurgery. Journal of Biomechanical Engineering 126(2): 305-309, 2004

Electrical impedance tomography; the construction and application to physiological measurement of electrical impedance images. Medical Progress Through Technology 13(2): 69-75, 1987

In-cycle myocardium tissue electrical impedance monitoring using broadband impedance spectroscopy. Conference Proceedings 2011: 2518-2521, 2012

Real-time extraction of tissue impedance model parameters for electrical impedance spectrometer. Medical & Biological Engineering & Computing 37(4): 428-432, 2000

Real-time extraction of tissue impedance model parameters for electrical impedance spectrometer. Medical & Biological Engineering & Computing 37(4): 428-432, July, 1999

A study of electrical impedance of oedematous cerebral tissue during operations. Correlation of impedance with water and electrolyte content and with histology. Acta Neurochirurgica 27(3): 113-124, 1972

Electrical impedance tomography for imaging tissue electroporation. IEEE Transactions on Bio-Medical Engineering 51(5): 761-767, 2004

Spatial resolution in the electrical impedance tomography for the local tissue. Conference Proceedings 6: 6638-6641, 2007

Tissue spectroscopy with electrical impedance tomography: computer simulations. IEEE Transactions on Bio-Medical Engineering 42(9): 948-954, 1995

Electrical impedance endo-tomography: imaging tissue from inside. IEEE Transactions on Medical Imaging 21(6): 560-565, 2002

A two-layered forward model of tissue for electrical impedance tomography. Physiological Measurement 30(6): S19-S34, 2009

Electrical Impedance Tomography: Tissue Properties to Image Measures. IEEE Transactions on Bio-Medical Engineering 64(11): 2494-2504, 2017